7

6

MEDICAL SAFEGUARDS

Please note the following instructions for your continued 
safety.
1.  Similar to starting any new oral hygiene product, 

contact your dentist before using SoniDent if you have 
had oral or periodontal surgery.

2.  Contact your dentist if excessive bleeding occurs or if 

bleeding continues after 2 weeks.

3. This product is designed for cleaning teeth and gums 

only. Do not use for any other purpose.

Warning: Individuals with pacemakers should consult 
a physician prior to use.

SPECIAL INSTRUCTIONS

REMOVING AND DISPOSING OF NI-CAD BATTERIES

SoniDent is equipped with long-lasting, rechargeable 
nickel-cadmium batteries. To help protect our environment,
they should be removed at the end of the unit’s life for safe
disposal. Batteries CANNOT be replaced.

To remove the batteries before discarding product:

1.  Place the handle in the charging base and turn 

counter clockwise to remove the cap.

2.  Slide the battery out of the SoniDent handle and 

remove.

3.  Dispose of the cell-pack in compliance with national or 

local regulations for environmental protection and 
recycling of raw materials. Do not dispose of the 
cell-pack by burning or incineration.

Caution:
Opening the
handle will
destroy the
appliance and
invalidate the
warranty.

Note: During the
first few days of
using, your
gums may bleed
slightly. Any
bleeding should
stop within a
few days. If your
gums continue
to bleed for a 
period of 2
weeks or more,
discontinue use
and consult
your dentist.

11.Brush heads should be replaced every 2-3 months to

ensure optimal performance.

HoMedics replacement brush heads (RH-S) for this
model are available at your local retailer or check
www.homedics.com for a list of retailers that offer these
replacement heads.

CLEANING AND MAINTENANCE

1. After use, rinse the brush head for several seconds 

under running water with the handle switched on.

2. Switch off the handle and take off the brush head.

3. Rinse both parts separately under running water 

and wipe them dry. Note: Be sure to point the 
handle downward (upside down) when rinsing. Do 
not allow water to drain down into the handle.

4. After cleaning place the handle back on the 

charging base. Note: For optimal charging base 
stability, run the power cord through the right or left 
slot on the back of the charging base.

5. When SoniDent is not in use for an extended 

period, unplug the cord and store.

6. Clean the charger base periodically with a soft cloth

or paper towel. The charger base must be dry 
before plugging it into an electrical outlet.

Note: To maintain
optimal 
performance, we
recommend that
you replace your
brush head every
2-3 months.

Note: We recom-
mend soaking
the brush head in
a denture cleaner
(commercially 
available) every 2
to 4 weeks to
keep it 
hygienically
clean.

Caution: All 
servicing of this
unit must be 
performed by 
authorized
HoMedics 
service 
personnel only.

Summary of Contents for SoniDent HD-510C

Page 1: ...o enviarla por correo junto con su recibo de compra fechado como prueba de la compra el franqueo pagado junto con un cheque o una orden de pago por el monto de 5 00 pagadero a HoMedics Inc para cubrir los gastos de manipulación Una vez recibido HoMedics reparará o reemplazará su producto según lo que sea apropiado y se lo enviará con el franqueo pagado La garantía es válida únicamente a través del...

Page 2: ...th 2 color coded brush heads for multiple users IMPORTANT SAFEGUARDS WHEN USING ELECTRICAL PRODUCTS ESPECIALLY WHEN CHILDREN ARE PRESENT BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED INCLUDING THE FOLLOWING READ ALL INSTRUCTIONS BEFORE USING DANGER TO REDUCE THE RISK OF ELECTROCUTION DO NOT handle the plug with wet hands DO NOT place or store the charger base where it can fall or be pulled in...

Page 3: ...ff before the 2 minutes have elapsed simply press the OFF button 9 Rinse mouth thoroughly with water 10 Remove brush head and rinse under running water SoniDent the easy to use sonic plaque remover will enhance your oral hygiene The rapid movement of the SoniDent disrupts plaque beyond the bristle tips for a more thor ough clean with less effort CHARGING INSTRUCTIONS Follow this procedure before y...

Page 4: ... bleeding should stop within a few days If your gums continue to bleed for a period of 2 weeks or more discontinue use and consult your dentist 11 Brush heads should be replaced every 2 3 months to ensure optimal performance HoMedics replacement brush heads RH S for this model are available at your local retailer or check www homedics com for a list of retailers that offer these replacement heads ...

Page 5: ...rchase postpaid along with check or money order in the amount of 5 00 payable to HoMedics Inc to cover handling Upon receipt HoMedics will repair or replace as appropriate your product and return it to you postpaid If it is appropriate to replace your product HoMedics will replace the product with the same prod uct or a comparable product at HoMedics option Warranty is solely through HoMedics Serv...

Page 6: ...NCIA PARA REDUCIR EL RIESGO DE QUEMADURAS CHOQUE ELÉCTRICO INCENDIO O LESIONES NO doble demasiado ni tire del cable Desenchufe el cable tomando el enchufe no el cable Mantenga el cable alejado de superficies calientes Utilice este producto sólo para el uso para el cual fue diseñado y como se describe en este manual NO utilice el producto con ningún otro fin NO utilice accesorios no recomendados po...

Page 7: ...ad por no menos de 16 horas antes de usarla por primera vez CÓMO USAR EL SONIDENT 1 Sujete la cabeza del cepillo al mango colocando la cabeza a un ángulo de 900 hacia la izquierda del mango Ver Fig A Gire la cabeza del cepillo un cuarto de giro en sentido antihorario en modo que las cerdas queden en la misma dirección del botón on off y la cabeza de cepillo quedará fijada en su lugar Ver Fig B 2 A...

Page 8: ...e agua al mango 4 Después de limpiar coloque el mango nuevamente en la base cargador Atención Para la máxima estabilidad de la base cargador pase el cable a través de la ranura derecha o izquierda en la parte de atrás de la base car gador 5 Si no se usa el SoniDent por un largo período de tiempo desenchufe el cable y guarde la unidad 6 Limpie la base periódicamente con un paño suave o una toalla d...

Reviews: