10 

 

2. Safety Warnings 

2.1. General Instructions 
Signs used to mark instructions in this manual 

Safety instructions in these operating instructions, 

which, if not observed, could cause a danger for persons 
are marked with the general symbol in accordance with 
DIN 4844-W 9. 

Warnings against electrical voltage are marked with 

the safety symbol in accordance with DIN 4844-W 8. 
 

2.2. General Safety Precautions

 

General regulations and guidelines not mentoined in the  
safety warnings retain their validity. 

These operating instructions contain basic instruc-

tions, which have to be adhered to during installation, op-
eration and maintenance. These operating instructions 
must be read from mechanic and the operator before in-
stallation and operation of the pump and have to be kept 
available at the operating place of the machine/unit at all 
times. Persons who are not familiar with the operating in-
structions shall not use this product. 

Children and adolescents under age 16 shall not use 
the pump and must keep away from the machine/unit  
while it is operational.

 

The working area has to be closed off expediently 

and must adhere to local workplace regulations. 

Always use personal safety equipment such as safety 

boots, rubber gloves, safety glasses and helmet. 

Make sure that the emergency exit from the workplace 

is not barricaded. 

To prevent suffocation and poisoning caused by ven-

omous gases, make sure that enough oxygen exists at the 
workplace. 

If you have to work with welding tools or electric tools, 

make sure that there is no explosion hazard. 

Immediately after repair or maintenance work, all 

safety and protection equipment must be reinstalled and 
placed in function again. 

The operator of the pump is responsible for third par-

ties within the work area. 

Never put a hand or finger into suction inlet or dis-

charge of the pump while the impeller is rotating. 

Persons are not permitted to stay in the pumping me-

dium during operation of the pump. 

All other rules and regulations and local codes cover-

ing health and safety must be observed. In accordance 
with product liability law, we point out that we shall not be 
liable for damages caused by the pump due to non-
observance of the instructions and guidelines set forth in 
the operating instructions. The same product liability are 
valid for accessories. 
 

3. Applications and Technical Description 

3.1. Application 

Waste water submersible pumps must be fully submerged 
in the pumped medium. TCV pumps are designed for 
pumping dirty water like rain water or ground water with 
solid sizes: 

The pumps are used for pumping water from basements, 
cellars or surface water from sumps. 
The pumps must not be used for pumping of liquids con-
taining great quantities of abrasive solids, like sand or 
stones. Before the pumping of chemically aggressive liq-
uids, the resistance of the pump materials must be 
checked. 

If the pump is used for cleaning or maintenance of 

swimming pools, make sure that no persons stay in the 
swimming pool during operation of the pump and that the 
pump is self-assured by a 30 mA earth leakage circuit  
breaker. 

The voltage required in the technical data sheet 

must correspond to the existing line voltage. 

3.2. Technical Data 

Discharge 

BSP 2“ F 

Voltage 230 

Speed 2900 

rpm 

Insulation class 

Motor protection 

IP 68 

Max. Noise level 

 70d(B)A 

 

3.3. Operating Conditions 
Maximum liquid temperature:

 35°C, short term up to 

60°C. 

Density of pumped liquid:

 max. 1100 kg/m

3

 

Ph-value of pumped liquid:

 5 up to 11. 

Level of pumped liquid:

 The lowest level must always be 

above the top of the pump housing (volute). 

Operation:

 The motors are designed for continuous op-

eration (S1) with fully submerged motor, maximum 15 
starts per hour. Our standard warranty and maintenance 
regulations refer to intermittent operation. For reduced 
warranty periods and service intervals due to continuous 
operating conditions please contact our service 
department. 

3.4. Explosive Enviroments

 

For operation of the pumps in explosive enviroments 

only models with explosion-proof motors (s. HOMA prod-
uct range) must be used. 

For each individual installation the explosion classifi-

cation (Ex-class) of the pump must be approved by the 
local authorities. 
 

4. Warranty 

Our warranty only covers pumps which are installed and 
operated in accordance with these installation and opera-
tion instructions and accepted codes of good practice and 
being used for the applications mentoined in these instruc-
tions. 
 

5. Transport and Storage 

Never use the cable or the discharge hose/pipe to lift, 

lower, transport or attach the pump. Always use the han-
dle or a rope or a chain attached to the handle. 

The pump may be transported and stored in vertical 

or horizontal position. Make sure that it cannot roll or fall 
over. For longer periods of storage, the pump should be 
protected against moisture, frost or heat. 

Summary of Contents for TCV 409 Series

Page 1: ...Original Betriebsanleitung Original Instruction Manual HOMA Pumpenfabrik GmbH 02 2011 Industriestr 1 D 53819 Neunkirchen Seelscheid Baureihe Series TCV 409...

Page 2: ...2 Inhalt Contents Seite 3 Page 9 Seite 14 Page 14 DEUTSCH ENGLISH Bauma e Dimensions...

Page 3: ...f hrung den einschl gigen grundlegenden Sicherheits und Gesundheitsanforderungen der EG Maschinenrichtlinien entsprechen Bei einer nicht mit uns abgestimmten nderung der Pumpen verliert diese Erkl run...

Page 4: ...h unser Ger t verur sacht werden wenn die Hinweise und Vorschriften aus dieser Bedienungsanleitung nicht eingehalten werden nicht haften F r Zubeh rteile gelten die gleichen Be stimmungen 3 Einsatz un...

Page 5: ...Installation Maximale Eintauchtiefe beachten siehe Typenschild Bei Verwendung im Schachtbetrieb ist die Schacht ff nung nach Montage der Pumpe mit einer trittsicheren Ab deckung zu versehen Folgesch...

Page 6: ...4 Pumpe am Schaltger t in ge w nschter Betriebsart in Betrieb nehmen manueller Dau erbetrieb oder niveauabh ngiger Automatikbetrieb 9 Wartung und Reparatur Bei einem eventuellen Defekt der Pumpe d rf...

Page 7: ...Abfall von Elektro und Elektronikger ten zu den daf r bestimmten Sammelstellen zu bringen Durch isolierte Sammlung und ordnungsgem e Wiederverwendung Ihres elektrischen und elektronischen Abfalls k nn...

Page 8: ...ingen 03 31 740 40 70 0 74 31 95 83 24 Naumann Pumpen GmbH Co KG G Meier GmbH Am Wall 11 Gustav Schwab Str 16 14979 Gro beeren 72762 Reutlingen 03 37 01 52 50 0 71 21 26 90 0 HEKO Pumpen GmbH Pumpen Z...

Page 9: ...d construction the following pump types in the form in which they are marketed by us conform to the relevant fundamental safety and health re quirements of the EC Machine Directives TCV 409 EC Directi...

Page 10: ...s 3 Applications and Technical Description 3 1 Application Waste water submersible pumps must be fully submerged in the pumped medium TCV pumps are designed for pumping dirty water like rain water or...

Page 11: ...tion of the guide rail bracket on the inside of the pit cover Drill mounting holes and fasten the guide rail bracket provi sionally with 2 screws Put the auto coupling base unit in the exact position...

Page 12: ...the pump following points should be checked regularly Nominal current A Check with amp meter Pump parts and impeller Check for possible wear Replace defective parts Ball bearings Check the shaft for n...

Page 13: ...ra dial shaft ring change the oil Pump operates but gives no liquid Discharge valve closed or blocked Check the dis charge valve and possibly open and or clean Non return valve blocked Clean non retu...

Page 14: ...A B D E F G TCV 407 R 2 AG 180 221 95 400 180 Schachtinstallation mit Kupplungssystem Submerged Installation with auto coupling 13 Ersatzteilliste und Zeichnungen 13 Spare part list and drawings 13 1...

Page 15: ...g 550 02 U Scheibe Ring 550 03 U Scheibe Ring 732 Schwimmerhalter Float switch holder 800 Motor compl 812 01 Motorgeh usedeckel Motor housing cover 812 02 Deckeleinsatz Cover inset 822 Motorlagergeh u...

Page 16: ...53819 Neunkirchen Seelscheid Fax 49 22 47 7 02 44 Pump type see pump label Year of construction see pump label Position number of the spare part 1 2 3 4 Part description of the spare part 1 2 3 4 Requ...

Page 17: ...xisch nein ja welche Stoffe _____________________ tzend nein ja welche Stoffe _____________________ mikrobiologisch nein ja welche Stoffe _____________________ explosiv nein ja welche Stoffe _________...

Page 18: ...______________ corrosive no yes which substance __________________ microbiological no yes which substance __________________ explosive no yes which substance __________________ radioactive no yes whic...

Page 19: ...17...

Page 20: ...18...

Reviews: