N O T I C E
Operation is only allowed with safety switch against
stray current (RCD max. stray current of 30mA)
N O T I C E
Use only permitted extension cable with cross-section
the one in the following table declared.
Voltage
Extension
Cross-section
220 V-240 V
50 Hz
<27 m
1,5 mm
2
<44 m
2,5 mm
2
<70 m
4,0 mm
2
<105 m
6,0 mm
2
13.3
Assembly
13.3.1
Loader
Fit the loader in its housing by means of the 2 screws
A
Loose knob
B
and remove the cover of the loader
Adjust the 3 rods
C
to the internal diameter of the band roll
Place the pre-glued band roll in the support, return the cover to the loader
D
and rescue it
by means of knob
B