background image

Holtkamp Electronics UNO 7600XL engl.                        techn. Stand 04.2016                                              4050_04.2016 V09.2019

- 24 -

Display shows

Factory setting

Description

Token counter

The token counter offers the possibility, to install a further counter, which counts 

separately the inserted token. (Else the amounts are added to the cash coun

-

ter). There  is  the  possibility  to  activate  2  token. These  indicate  the  value  of 

the EMP channel 5 and 6 to the token counter 5 and 6. Please notice that the 

channel 6 of the EMP is equipped for Holtkamp token. Channel 5 is therefore 

for your own token equipped. 

If you liked to use own tokens, our electronic coin tester must be pro-

grammed on these coins. Please absolutely to specify by your order!

Token impuls 

counter 5

no

 

● If “yes” is set up, in the statistic menu will be shown the daily token coun-

 

      ter and total token counter. The value of token has to be set up under the 

 

      menu item “coin tester valuing channel 5”. Factory setting is value “0”.

 

● If “no” I set, the token counter is deactivated.

Token impuls 

counter 6

no

 

● If “yes” is set up, in the statistic menu will be shown the daily token counter 

 

      and total token counter. The value of the token is on “3,5” factory set up 

 

        and is put out to channel 6 on EMP. If you want to change the value of the  

     Holtkamp token, you will have to set it up from menu item “coin tester 

 

      valuing”.

 

● If “no” I set, the token counter is deactivated.

Daily counter 

yes

The daily counter setting offers the possibility to display all the daily counters 

in the statistic menu or not.

 

● If “yes” is set, all available daily counters will be displayed.

 

● If “no” is set no daily counters will be displayed. 

3 digits main time

no

The 3 digits main time offers the possibility to show the main time in 2 or 3 digits 

on the display. 

 

● If “no” is set, main time will be displayed in 2 digits and so limited to 99 min 

 

     or 1 hour 39 min.

 

● If “yes” is set, the main time will displayed in 3 digits.

Memory lock 

no

The memory lock offers the possibility to obviate the repeated sale of main time.

 

● If “yes” is set the main time can be bought only once.

 

● If “no” is set, can the main time repeatable sold.

Mains failure

fuse

The mains failure fuse offers the possibility that the main time remains even 

after a mains failure. After the mains supply is restored again, the devices with 

the stored main time will be switched back on, per random time generator, to 

prevent a mains overload.

 

● If “yes” is set, the same main times and prices apply irrespective if pay-

 

     ment is made cash or by card.

 

● If “no” is set, differing main times and prices will set for payment cash or 

 

     by card.

Summary of Contents for UNO 7600/XL

Page 1: ...Operating instruction UNO Coin timer ...

Page 2: ...or safe and proper use read the instructions for use and further product related documents carefully and keep it for later use For errors technical errors printing errors and incompleteness we assume no liability ...

Page 3: ...execution brought by us in traffic corresponds to the standards specified down Diese Erklärung gilt für alle Geräte die nach den beiliegenden technischen Unterlagen welche Bestandteile dieser Erklärung sind hergestellt werden This explanation applies to all devices after the enclosed technical documents which are components of this explanation are manufactured Einschlägige EG Richtlinien Relevant ...

Page 4: ...rogramming 14 12 Time price menu 15 13 Clock menu 18 14 Configuration menu 20 15 Bus configuration menu 25 16 Statistics 26 16 1 Enquiring the statistic values in operation mode Timer 26 16 2 Cancelling the statistic values or the counter readings 27 16 3 Enquiring the failure statistics 27 16 4 Cancelling the failure statistics 28 17 Not programmable special equipments 28 17 1 Electric contactor ...

Page 5: ... months The warranty is limited solely to technical defects of the unit it can t be accepted further claims Further apply our general terms and conditions stand of June 2011 for products and services of the electrical industry ZVEI also see website www holtkamp de Any liability extinguished by the manipulation of the device 3 Safety notices The coin boxes are built according to the prior art and t...

Page 6: ...ls will constitute an advantage Please note all the abbreviations appearing on the display definitely for any other technical requests in the follo wing list 6 General details Casing material Stahlblech verzinkt 2 mm Casing colour pulverbeschichtet weiß RAL 9016 Dimensions H 300 mm x B 218 mm x T 141 mm Power supply 230 V oder 24 V 50 60 Hz Switched power 6 3 A bei cos phi 1 Power absorption 10 VA...

Page 7: ...oin return button 5 Coin return 6 Beschriftungsfeld 7 Labeling field 8 Key 9 Card socket 10 Coin bag 11 Locking plate 12 Holes for 13 13 Fixing bolts for locking plate 14 Mounting bolts for the housing 15 Cable entrances 16 Earth terminals 17 SB frame 18 Securing holes 19 Rear wall 20 LCD display 21 operating light LED 1 2 3 4 5 6 7 8 10 11 12 13 14 18 15 16 14 18 17 14 15 19 20 21 9 ...

Page 8: ...elay 7c Run out relay 8a Fuse main relay 8b Fuse run out relay 9 Electrical connection 10 Connections for potential free relay contacts 11 Fuse printed circuit board 12 Connection for foil keyboard 13 Connection for external timer 14 DIP switch no 1 4 15 Connection for remote control 16 Connection for Zeitstopp time stop or cleaning button or delete button Special equipment Circuit board XL2_V021 ...

Page 9: ...serted coins There are 6 holes in the back of the casing to accomplish the mounting pro cess Screws and dowels are included by delivery The device must be mounted horizontally and vertically to guarantee a flawless function of the coin receiver That means the angle of the device can only be maximum 2 sloping forward or backward as well as to the right or the left Thedevicemustbemountedperpendicula...

Page 10: ...nt connection an all pole mains se parator with at least 3 mm contact gap must be used Before starting the electric the corresponding circuit must be disconnec ted Shut down the mains input by activating the separator switch remove the fuse or release the main safety fuse Mains and low voltage cable must be spaced apart Low voltage cables should be generally spaced as screened cables Control cable...

Page 11: ...he sun bed Do not choose the main time too long because of the danger of the sun bed customer Use the adjustment setting to limit the maximum time and therefore limiting the maximum account of buyable main time to reduce to a minimum the danger to the customer 8 5 1 LED operating light With the LED operating light one can see at a glance the ope rating stand of the UNO During the pre run time quic...

Page 12: ...dentification electronic cash counter electronic operating hour counter electronic service hour counter electronic customer counter electronic de and revalue counter electronic token counter 2 times Contactor 20 x 2 A Time stop cleaning button delete button Remote control Remote start Master card owner once per commission Statistic Request card owner staff LED operating light Design foil see broch...

Page 13: ...enu through singularactua tion another actuation call up the clock menu another actuation call up the configuration menu The normal mode is active again through a furtheractuationofPROG button Through actuation the NEXT button the statistic menu is call up and it shows the first statistic position The follow statistic positions you call up through a further actuation The adjusted values can be inc...

Page 14: ...ock menu the configura tion menu the Summer wintertime menu and the Bus confi guration menu You can leaf through forward and backward the paricular programming positions in a smart passage autorepeat function You must insert the master card at first Call up the res pective menu with PROG button Is desired a smart leaf through you must actuate the NEXT button permanent If the button depressed it wi...

Page 15: ...een payment at the coin or chip card timer and the start of the connecting device It can be adjusted in steps of 5 seconds to a max of 9 min 55 sec The pre run count down can be prematurely interrupted by the remote start Remote start The remote start offers the possibility of triggering the remote start via an ex ternal button In the first case the pre run time is set on lower than 0 In this case...

Page 16: ...lity to note a certain operating time After reaching the third service hour time counter it will switch to price 2 and or time 2 FairPlay must be activated in the payment type of the configuration menu FairPlay Stufe 2 200 Std Analogue FairPlay step 1 however it will switched over to price 3 FairPlay step 1 must be set smaller than FairPlay step 2 and FairPlay step 2 must be adjusted smaller than ...

Page 17: ...paid yet during the run out time The pre run time of the new purchased main time will be cleared with the remaining run out time at the time of payment If this function is not activated the run out time does not matter the main time starts after end of the pre run time If the forced remote start activated forced remote start active if pre run time 0 the device starts only at the end of run out tim...

Page 18: ...ster card press PROG button 2 x The settings for the following positions are important for the error free flow of the functions Happy hour and summer winter time conversion Display shows Factory setting Description Current time S 17 24 41 The current time offers the possibility to set the current hour and minute By pressing the MINUS button the hours will be counted up By pressing the PLUS button ...

Page 19: ...riff 1 2 Then enter time switch Monday Friday 2 14 00 now enter after tariff 2 1 By switching times the hours will be counted up by pressing the MINUS button The minutes will be changed by pressing the PLUS button A payment is not possible during activated blockage Switch time Mo Fr 1 First switching time valid from Monday to Friday Tariff Mo Fr 1 First tariff valid from Monday to Friday The tarif...

Page 20: ...l accept the coins but there will be no time buying If the coin should be blocked this change should be set up in the coin tester Coin tester value channel 2 6 Analogue coin tester value channel 1 The language selection is depending on the respective software ver sion Language Coin tester value channel 1 Coin tester value channel 2 Coin tester value channel 3 Coin tester value channel 4 Coin teste...

Page 21: ...oin acceptor EMP in UNO 1 coin was thrown in 2 coin is assigned the channel in the EMP 3 Exit channel of EMP is as signed the Entrance of UNO 4 the entrance of UNO is assigned by the factory or individually the programs value EUR 0 50 1 E1 e g 0 50 EUR by the factory EUR 1 00 2 E2 e g 1 00 EUR by the factory EUR 2 00 3 E3 e g 2 00 EUR by the factory EUR 0 20 4 E4 e g 0 20 EUR by the factory 5 E5 e...

Page 22: ...tivating coin accep tance yes In the basic adjustment of the EMP the channels for 0 2 Euro and the tokens are closed Notes for the electronic multi coin acceptor Your UNO is equipped with an electronic multiple coin acceptor Please consider the following noticing Well worn dirty damaged false and foreign currency coins will not be accepted If an apparently good coin is not accepted please use an o...

Page 23: ...time 3 the customer receives main time 3 The prices and times must be increasing programmed Meaning that price 1 must be smaller than price 2 price 2 must be smaller than price 3 and the same applying for the main times In case of paying more as price 3 the minimum insert function is automatically activated The function minimum insert in the configuration menu can also be activated In this case it...

Page 24: ... put out to channel 6 on EMP If you want to change the value of the Holtkamp token you will have to set it up from menu item coin tester valuing If no I set the token counter is deactivated Daily counter yes The daily counter setting offers the possibility to display all the daily counters in the statistic menu or not If yes is set all available daily counters will be displayed If no is set no dai...

Page 25: ...Jedes XL Gerät muss eine andere Gerätenummer bekommen Es dürfen kei ne Nummern doppelt vergeben werden sonst ist das Bus System nicht in der Lage die jeweilige Adresse auszulesen Außerdem müssen die Gerätenum mern mit den im SkinControl eingestellten Nummern und der zugehörigen Kabine dem jeweiligen Solarium übereinstimmen Card verify no This setting must be set generally to no If yes is set no co...

Page 26: ...amp token 6 digits Total customer impulse counter counts the numbers of relay switching 5 digits NEXT insert master card query card You call up the statistic menu through insert the master or re quest card and pressing the NEXT button With a further actuati on of NEXT button you can leaf through Total operating hours impulse counter counts the numbers of relay switching 6 digits The total operatin...

Page 27: ...lete You leaf through to the next position with NEXT button see autorepeat function chapter 5 General at programming The UNO offers following failure statistics in a special menu Watchdog Reset counter Numbers of error messages The last 8 error messages 16 3 Enquiring the failure statistics In normal mode you must insert the master card and actuated the PLUS button During you hold the PLUS button ...

Page 28: ...de red together with the special equipment time stop or an external short impulse for the washing machine door 17 5 Internal short time impulse for washing machine door opening The short time impulse for washing machine door opening offers the possibility to turn on the connected device for 30 se conds The door opening started with pressing the reject button on the coin tester After any activation...

Page 29: ...start but ton If your UNO has been ordered with a remote start button you can find on the SB frame on the inside of the back of the device an additional circuit board which needs to be connected to the remote indication as following The needed connection cable is not included by delivery Connection to the XL with 4 pol installation cable shielded screen on one side presented maximum conduit length...

Page 30: ...ge for approx 10 seconds The electronic multiple coin tester takes on sporadic coins only coin tester is dirty bad quality of coins clean the coin tester use another coin chosen a narrow adjustment change the adjustment on DIP switch from the EMP see also coin tester values The electronic multiple coin tester is de fectively send the electronic multiple coin tester to repair The coin remains hangi...

Page 31: ... error message E20 DIP switch no 2 is on on set DIP switch no 2 on off The display shows error message E27 By FairPlay the two FairPlay steps and the 3 service interval must be program med in ascending order FairPlay step 1 must be smaller or even step 2 step 2 must be smaller or even with the service interval 3 The display shows error message E32 By bonus operation No discount could be assigned b...

Page 32: ...Holtkamp Electronics UNO 7600XL engl techn Stand 04 2016 4050_04 2016 V09 2019 32 ...

Page 33: ...s 21 Enquiring the failure statistics 27 F Function of chip card types 13 G General details 6 I Illustration of electronic 8 Illustration of the device 7 Installation notes 9 Internal short time impulse 28 K Key switch for free use 28 L LED operating light 11 Legal information 5 M Maintenance 5 Malfunctions 30 31 Master card 13 Mounting instructions 9 Mounting notes 9 N Not programmable special te...

Page 34: ...Holtkamp Electronics UNO 7600XL engl techn Stand 04 2016 4050_04 2016 V09 2019 34 ...

Page 35: ...Holtkamp Electronics UNO 7600XL engl techn Stand 04 2016 4050_04 2016 V09 2019 35 ...

Page 36: ...de Technical Stand 09 2019 We reserve the right to technical changes in the production and technical developments For technical information during our business hours Monday Thursday 8 00 a m 16 00 p m and Friday 8 00 a m 13 00 p m choose 49 541 97120 0 or visit our homepage www holtkamp de ...

Reviews: