8.4 Electrical connection
The electrical connection can only be carried out by
authorized and qualified personnel!
The electrical connection has to be carried out by the local VDE
regulations. With a permanent connection, an all pole mains se
-
parator with at least 3 mm contact gap must be used. Before
starting the electric the corresponding circuit must be disconnec
-
ted.
Shut down the mains input by activating the separator switch,
remove the fuse or release the main safety fuse. Mains and low
voltage cable must be spaced apart. Low voltage cables should
be generally spaced as screened cables.
Control cable and remote start connection have to be
kept away from each other!