E236 Data error in the object data configuration menu. Read the
menus completely and check all values!
E237 Data error in solarium data (checksum error) of the skin mea-
suring head. The calculation of tanning times can
not be carried out! The device must be reinitialized (see
chapter „
Reset to factory data
“). Maybe it helps a reset
of the device.
E238 This device already has more recent software installed!
The database or data structure therefore not be fully
supported maybe.
E239 Card value (time account) is higher as the card maxi-
mum value (= original value)! or the card value is nega-
tive!
E243 The digital skin measuring head (DHMK) must be cali-
brated!
E246 RAM error (If this error occurs again and again after
switching the operating voltage off and on, there is a
technical defect and the device is blocked. Note: Wait 5
seconds between switching off and on again!).
E247 ROM checksum error (If this error occurs again and
again after switching the operating voltage off and on,
there is a technical defect and the device is blocked.
Note: Wait 5 seconds between switching off and on
again!).
E248 Takt error (The quarz takt of the controller is periodically
checked with the help of the RTC time).
E249 Error initializing the RTC (Real Time Clock). Possible
cause: Quartz oscillator is not working (Sub-Clock).
E261 Chip card revaluation (personal uses, by revaluation
chip card type 73): The bonus steps must be program-
med in ascending order: step 1 must be smaller (or
same) than step 2, step 2 must be smaller (or same)
than step 3 etc.
E262 Chip card revaluation (personal uses, by coin insert):
The bonus steps must be programmed in ascending or-
der: step 1 must be smaller (or same) than step 2, step
2 must be smaller (or same) than step 3 etc.
E263 Editing or revaluating function is not activated. There
are several possible causes for this error message: in
the programming menus are neither approved the re-
valuation by cash (e. g. coin insert) still by revaluation
chip card type 73, or edit/revalue mode has not been
activated with revaluation chip card type 73.
E264 This type of chip card is blocked until the end of the
time, another time purchase is not possible!
(The main time was started by a test chip card, another
test chip card or normal chip card is currently not accep-
ted and vice versa.)
E265 Selected cabin (tanning bed) is not supported by Skin
Control!
E266 Two object/cabin numbers are set identically, this is not
allowed!
E267 The prices must be programmed in ascending order, i.e.
price 1 must be smaller than price 2, price 2 must be smal-
ler than price 3 etc.
E268 The main times must be programmed in ascending order,
i.e. main time 1 must be smaller than main time 2, main
time 2 must be smaller than main time 3 etc.
E269 The maxium times must be programmed in ascending or-
der, i.e. maximum time 1 must be smaller than maximum
time 2, maximum time 2 must be smaller than maximum
time 3 etc.
E270 The maximum time (or one of the maximum times) is set to
„0“!
E298 Data error in the menu call password data. Read the menus
completely and check all values!
E299 Data error in (transmission) error log. Read the menus
completely and check all values!
E300 Data error in the Login/Data encryption password data (for
data transfer! Error by reading the data from the EE
PROM)!
E305 Data error in the service interval data. Read the menus
completely and check all values!
E306 Data error in the event log data. Read the menu completely
and check all values!
E352 Data error in the revaluating menu. Read the menu comple-
tely and check all values!
E353 Data error in the maintenance menu. Read the menu com-
pletely and check all values!
E354 Data error in the Shifting times menu (Happyhour). Read
the menu completely and check all values!
E355 Skin measuring head is missing or defective!
E356 Expansion board 1 is missing or defective!
E357 Legitimation chip card type 103 was inserted. Here you can
change only the date of birth, but this function is switched
off in the menu „
Chip card edit./revaluating
“!
E358 A test chip card type 16 was inserted. Editing and revalua-
tion are not allowed!
E359 A test chip card type 14 or 15 was inserted. Revaluating not
possible, because this option was switched off in the
menu „
Chip card edit./revaluating
“. (Editing is not allo-
wed!).
E412 XXL power board is missing or defective (no UART con-
tact)!
E431 Currency of the EMP (coin validator on the Multi-Drop-Bus
„MDB“) and the XXL device do not match! You must either
set both to „Euro“ or both to any other currency!
E432 EMP (coin validator on the Multi-Drop-Bus „MDB“): no pa-
rameter set fits (the inserted coin is not programmed in the
EMP, or the coin is damaged a.o.)