Holtkamp Electronics DUO XXL techn.stand 01.2018 4022_01.2018/V05.2020
- 26 -
15.2 Times and Prices
The switch-on delay is out of service if you set „0” here. Then
the main time starts the main time either immediately (when no
remote control is activated), or she will start after activating the
remote control (see „Configuration/Div. operating parameter/Re
-
mote control”).
If a value is higher than „0” set, ensued the start of the main time
after expirati on of the lead time (a pre run time can be interrup-
ted premature by the remote control).
The run out relay is switched on during the main time and then
during the set duration (Fan overrun by tanning beds a.o.).
If you choose „
yes
” here, you cannot buy new main time during
over run time.
If you choose „
no
” here, you can buy new main time during over
run time.
Reset delay, cooling phase for HQL lamps.
If you choose „
yes
” here, you can buy new main time during over
run time, but the next main time will be started after the over run
time. If the pre run time expires before, or the remote control
button is pressed before, the start of the main time starts only at
the end of the over run time.
If you choose „
no
” here, you can buy new main time while run
out time.
The main time will be sold when you pay the current price. When
multiple payment of the price, the time will be added accordingly.
She definite the duty cycle of the main relay and safety relay.
The main settings vary depending on the configuration, see
„
Configuration/Div. operator parameter
” and „
Configuration/
Payment
”.
Definition by cases:
●
In the simplest case there is only one maximum time.
● Optionally, there are different main times for payment by
chip card and cash.
When different tariff changeovers („Payment method =
Happy hour”) are activated, there are several main times
(depending on „Amount of happy hour steps”), which are
activated at different daytimes (see „Configuration/Clock +
Shifting time”).
Maximum buying time.
If the maximum time limit is set to „0”, it will be out of order and
you can time unlimited.
Definition by cases:
●
In the simplest case there is only one maximum time.
● Optionally, there are different main times for payment by
chip card and cash
The actual maximum time may be less than set here, if it
is determined by skin measurement or skin type
(see „
Configuration/Tanning management/SkinControl
“
and „
Itegrated skin measurment head
“ and „
Tanning se
-
ries managen
“).
If several of these maximum times are activated, the
smallest is always valid. The maximum time can therefore
be less than the set main time!