Holtkamp Electronics DUO XXL techn.stand 01.2018 4022_01.2018/V05.2020
- 10 -
Control cable and remote start connection have
to be kept away from each other.
The electrical connection has to be carried out by the local
VDE regulations. With a permanent connection, an all pole
mains separator with at least 3 mm contact gap must be used.
Before starting the electric the corresponding circuit must be
disconnected. Shut down the mains input by activating the
separator switch, remove the fuse or release the main safety
fuse. Mains and low voltage cable must be spaced apart. Low
voltage cables should be generally spaced as screened cables.
7.3 Electrical connection
The electrical connection can only be carried out
by authorized and qualified personnel!
Outside of office hours, the XXL should be swit
-
ched off to preserve the image quality of the dis
-
play for as long as possible (minimize age-related
reduction of contrast and brightness)!
DUO XXL
DUO XXL
Fuse
over
run
Fuse
main r
.
violet
brown
protective conductor
green-yellow
blue
black
Remote
start
Fuse
over
run
Fuse
main r
.
violet
brown
protective conductor
green-yellow
blue
black
Remote
start
Connection 230 V~
Connection 24 V~