6.3
Changing the battery pack
The battery pack has a LED indicator that indicates the approximate battery level (the State Of Charge).
No lit LED indication will be shown during the operation of the tool.
Switch off the tool using the on/off switch.
•
Remove the battery pack.
•
Place a new battery pack on the tool.
•
Switch on the tool using the on/off switch.
6.4
Tool movement
The cutting blades open and close relatively quickly until they encounter resistance. Then the pump will
build up the required pressure for spreading, cutting, pulling or squeezing.
6.5
Cutting
•
Open the blades.
•
Place the tool with opened blades perpendicular to the object to be cut.
•
Place the object to be cut as deeply as possible in the cutting opening.
CAUTION
•
Many cycles in a short time may cause temperature increase above allowed limits. The
battery protection will shut down the battery until the temperature lowers to a value within
allowed limits.
•
Using the battery pack at temperatures above 45 °C (113 °F) reduces the life time of the
battery pack.
NOTICE
It is highly recommended to have at least one fully charged spare battery pack available at
all times.
NOTICE
To protect the battery pack, the tool will stop as soon as the battery pack gets empty. It might
happen that at that time the tool is fixated. To remove the tool it is best to replace the battery
pack by a fully charged one. When this is not possible the battery pack can be activated
again by pushing the SOC indicator button. To prevent damaging the battery pack, this can
only be done a limited number of times.
WARNING
Take extreme care during tool movement. Because of the enormous power of the tool parts
of the body can easily be crushed or pinched.
CAUTION
Do not cut hardened fastenings, bolts, etc. because this can damage the blades.
Summary of Contents for GCT 51 EVO 3 Series
Page 3: ...GCT 51 ST STA EVO 3 916 001 650_002 3 Fig 1 Fig 2...
Page 4: ...4 916 001 650_002 GCT 51 ST STA EVO 3 Fig 3 Fig 4 Fig 5 Fig 6 Fig 7 Fig 8 A C B B C A B A C B...
Page 157: ...PT GCT 51 ST STA EVO 3 916 001 650_002 157...
Page 158: ...ZH 158 916 001 650_002 GCT 51 ST STA EVO 3 1 1 1 1 2 1 3 i 1 4 1 5 1 5 1 1 6 1 7...
Page 159: ...ZH GCT 51 ST STA EVO 3 916 001 650_002 159 1 8 CE 2 2 1 2 2 Fig 1...
Page 160: ...ZH 160 916 001 650_002 GCT 51 ST STA EVO 3 i Pos A B C CE...
Page 161: ...ZH GCT 51 ST STA EVO 3 916 001 650_002 161 2 3 2 4 2 5 Fig 11...
Page 162: ...ZH 162 916 001 650_002 GCT 51 ST STA EVO 3 2 6 2 7 2 8 3 4 45 C 113 F...
Page 163: ...ZH GCT 51 ST STA EVO 3 916 001 650_002 163 2 9 2 10 EN ISO 12100 2 11 Greenline BPA285 BPA286...
Page 179: ...179 916 001 650_002 i Fig 9 Fig 10 Fig 11 Fig 12 90...
Page 180: ...180 916 001 650_002 GCT 51 ST STA EVO 3 Fig 13 Fig 14 A A B C 2 1...