3.8
Safety features of the battery pack
The battery pack is protected against:
•
Short-circuit
•
Deep discharge
•
Over- and under-voltage (of the battery pack and the individual cells)
•
Over-current during charging and discharging
•
Overcharging
•
Over temperature (of individual cells and electronics)
•
Charging and discharging outside the allowed temperature range
4
Preparation for first use
4.1
General
•
Check the equipment for completeness and damage. Do not use the equipment if it is damaged;
in that case contact the Holmatro dealer.
•
Check the operation of the deadman's handle. The deadman's handle must return to the neutral
position when you release it.
•
Before first use, always charge the battery pack completely. See section 5.3.
•
Check the state of charge of the battery by pressing the SOC indicator button for a few seconds.
See section 3.6.
•
Slide the battery pack in the battery pack fitting / adapter fitting until the battery pack lock snaps
tight.
•
Check the battery pack to ensure that the lock mechanism works correctly.
4.2
Installing the battery for the LED light
See Fig. 4.
The battery for the LED light is placed in the carrying handle. This battery has a working life of ± 6
hours.
•
Remove the cover (C) by unscrewing both screws (B).
•
Install the battery (A) in the battery holder of the carrying handle.
•
Re-install the cover and fasten the screws.
5
Operation
5.1
System operation
The GCT is a tool where the hydraulic pump is integrated in the tool. The hydraulic pump is driven by a
battery pack or from an external electric power source. This pump displaces hydraulic oil and is capable
of building up pressure. The hydraulic pump is connected directly to the hydraulic cylinder.
The hydraulic cylinder contains a piston that can move axially. If the cylinder is pumped full from the
bottom, pressure builds up beneath the piston so that it is pushed to the outside. If the cylinder is
pumped full from the top, the piston is forced back into the cylinder.
temperature range
°C
-20 + 55
°F
-4 + 131
Description
Unit
BPA285
BPA286
Summary of Contents for GCT 51 EVO 3 Series
Page 3: ...GCT 51 ST STA EVO 3 916 001 650_002 3 Fig 1 Fig 2...
Page 4: ...4 916 001 650_002 GCT 51 ST STA EVO 3 Fig 3 Fig 4 Fig 5 Fig 6 Fig 7 Fig 8 A C B B C A B A C B...
Page 157: ...PT GCT 51 ST STA EVO 3 916 001 650_002 157...
Page 158: ...ZH 158 916 001 650_002 GCT 51 ST STA EVO 3 1 1 1 1 2 1 3 i 1 4 1 5 1 5 1 1 6 1 7...
Page 159: ...ZH GCT 51 ST STA EVO 3 916 001 650_002 159 1 8 CE 2 2 1 2 2 Fig 1...
Page 160: ...ZH 160 916 001 650_002 GCT 51 ST STA EVO 3 i Pos A B C CE...
Page 161: ...ZH GCT 51 ST STA EVO 3 916 001 650_002 161 2 3 2 4 2 5 Fig 11...
Page 162: ...ZH 162 916 001 650_002 GCT 51 ST STA EVO 3 2 6 2 7 2 8 3 4 45 C 113 F...
Page 163: ...ZH GCT 51 ST STA EVO 3 916 001 650_002 163 2 9 2 10 EN ISO 12100 2 11 Greenline BPA285 BPA286...
Page 179: ...179 916 001 650_002 i Fig 9 Fig 10 Fig 11 Fig 12 90...
Page 180: ...180 916 001 650_002 GCT 51 ST STA EVO 3 Fig 13 Fig 14 A A B C 2 1...