PRECAUTION

CONTRAINDICATIONS

Introduction

Congratulations on your purchase of the WiTouch device. WiTouch is a unique wireless 

remote controlled pain relief device incorporating TENS technology to specifically target 

back pain. The thin and flexible design perfectly contours the back for maximum surface 

contact. The advanced electronics design maximizes energy use, providing over 150 

30-minute treatment sessions per battery life. 
This innovative device is safe, drug-free, easy to use, discreet and comfortable to wear, and 

most importantly allows you to control your pain to maintain an active lifestyle.
Indications for Use: For temporary relief of pain associated with sore and aching muscles 

in the lower back due to strain from exercise or normal household and work activities.  

WARNING!

• The device may cause rhythmic disturbances to the heart. Do not use the device across 

or through your chest. If you are susceptible to rhythm disturbances of the heart, use of 

the device must be done under the direction of a physician.

• Use of this device over your neck could cause muscle spasms resulting in airway 

closure, difficulty in breathing, adverse effects on heart rhythm or blood pressure.  

Do not use this device over your neck

• Use of the device when you are in the care of a physician or have had medical or 

physical treatment for your pain. Consult with your physician before using this device.

• Continued use of the device when pain does not improve, becomes more severe, or 

lasts more than five days may indicate a severe condition. Stop using the device and 

consult with your physician.

• Use of the device on the following skin conditions may cause a condition to become 

worse. Do not use the device over, or in proximity to, these skin conditions: abnormal 

skin, skin that is not intact, uncleaned, unhealthy, open wounds, rashes, swollen, red, 

infected, inflamed areas, skin eruptions (e.g., phlebitis, thrombophlebitis, varicose veins), 

or cancerous lesions.

• Electrical stimulation during common activities may increase the risk of injury. Do not 

use the device when in the bath or shower, sleeping, driving, operating of machinery or 

any activity in which electrical stimulation can put you at risk of injury.

• Using the device around electronic monitoring equipment (e.g., cardiac monitors, ECG 

alarms) may cause equipment malfunction. Do not use this device around electronic 

monitoring equipment.

• The effect, and safety, of using the device on children, during pregnancy, or use across 

the head has not been evaluated or established and is unknown. Do not use the device 

on children or let children handle the device. Do not use this device if you are pregnant, 

or suspect that you are pregnant, unless under the direction of your physician. Do not 

apply the device across your head.

• Using the device when you have suspected or diagnosed epilepsy or heart disease may 

cause unexpected reactions. Always consult your physician before using the device.

• Do not use this device if you have a cardiac pacemaker, implanted defibrillator, or other 

implanted metallic or electronic device. Such use could cause electric shock, burns, or 

electrical interference or death.

Safety

Summary of Contents for WiTouch

Page 1: ... on the remote control will flash several times indicating syncing is complete 5 Replace the back cover on the device Note You may need to re sync your remote control and WiTouch device when you replace the battery in the remote control This will ensure communication between your remote control and WiTouch device If your remote control and WiTouch device ever lose communication please repeat these...

Page 2: ...ere or lasts more than five days may indicate a severe condition Stop using the device and consult with your physician Use of the device on the following skin conditions may cause a condition to become worse Do not use the device over or in proximity to these skin conditions abnormal skin skin that is not intact uncleaned unhealthy open wounds rashes swollen red infected inflamed areas skin erupti...

Page 3: ...the Gel Pads to the WiTouch Device The gel pads are intended for single person use They will last depending on skin type oils and pH levels approximately two to five applications Replace the gel pads when they no longer adhere completely Follow these steps to apply the gel pads 1 Separate two gel pads 2 Remove the blue liner from the side being applied to the electrode area Do not remove the green...

Page 4: ...th a comfortable high sensory sensation Treatment Recommendations You can leave the device in position for multiple treatments during the day It will automatically turn Off after two 2 hours of inactivity It is recommended you wait a minimum of 30 minutes between treatments Conducting a Treatment Always read the safety warnings before conducting a treatment Follow these steps to conduct a treatmen...

Page 5: ...covered Battery Replacement When battery replacement is needed the LED will flash as follows To replace the WiTouch Device Batteries 1 Using the included 0 Phillips head screwdriver remove the cover 2 Remove the old batteries and place the new batteries in the correct polarity 3 Replace the battery compartment cover To replace the remote control battery 1 Place the provided screwdriver coin or fla...

Page 6: ...S Hollywog LLC Company warrants the WiTouch Product is free of defects in materials and workmanship This warranty shall remain in effect for 1 year 12 months from the date of purchase If these Products fail to function during the 1 year warranty period due to a defect in material or workmanship at the Company s Option Company or the selling retailer will replace the respective Product without char...

Page 7: ...cial or hospital environment NOTE UT is the a c mains voltage prior to application of the test level Guidance and manufacturer s declaration electromagnetic emissions The WiTouch and WiTouch Pro are intended for use in the electromagnetic environment specified below The customer or the user of the WiTouch or WiTouch Pro should assure that it is used in such an environment Emissions test Compliance...

Page 8: ...ctromagnetic propagation is affected by absorption and reflection from structures objects and people Guidance and manufacturer s declaration electromagnetic immunity The WiTouch and WiTouch Pro are intended for use in the electromagnetic environment specified below The customer or the user of the WiTouch or WiTouch Pro should assure that it is used in such an environment Immunity test IEC 60601 te...

Page 9: ...moto destellará varias veces indicando que la sincronización se completó satisfactoriamente 5 Vuelva a colocar la cubierta trasera en el dispositivo Nota Puede ser que necesite volver a sincronizar su control remoto y el dispositivo WiTouch cuando sustituya la pila en el control remoto Esto garantizará la comunicación entre su control remoto y el dispositivo WiTouch Si su control remoto y el dispo...

Page 10: ...más de cinco días puede indicar un trastorno grave Cese de usar el dispositivo y consulte a su médico El uso del dispositivo teniendo las siguientes condiciones en la piel puede provocar que se agrave la condición de la misma No use el dispositivo sobre o en la cercanía de estas condiciones de la piel piel anormal piel que no esté intacta que esté sucia enferma con heridas abiertas erupciones hinc...

Page 11: ...gel al dispositivo WiTouch Las almohadillas de gel son solamente para el uso de una sola persona Su duración dependerá del tipo de piel grasas y niveles de pH aproximadamente de entre dos a cinco aplicaciones Sustituya las almohadillas de gel una vez que ya no se adhieran por completo Siga estos pasos para aplicar las almohadillas de gel 1 Separe dos almohadillas de gel 2 Retire la cubierta azul d...

Page 12: ...oda estimulación sensorial alta Recomendaciones de tratamiento Puede dejar el dispositivo en posición para tratamientos múltiples durante el día Se apagará automáticamente después de dos 2 horas de inactividad Se recomienda que espere un mínimo de 30 minutos entre tratamientos Efectuando un tratamiento Lea siempre las advertencias de seguridad antes de efectuar un tratamiento Siga estos pasos para...

Page 13: ...completamente cubiertas De artículo Descripción Pila Dispositivo WiTouch El LED del destella una luz amarilla cada dos 2 segundos cuando la unidad está Encendida Pilas alcalinas AAA 2 El LED destella rápidamente en amarillo durante el tratamiento Control Remoto el LED del control remoto destellará en amarillo una vez cuando se presione el botón Inicio paro 1 pila de litio CR2032 Para sustituir las...

Page 14: ... EN NINGÚN CASO POR DAÑOS DIRECTOS O INDIRECTOS Hollywog LLC la Compañía garantiza WiTouch el Producto contra defecto en los materiales y la mano de obra Esta garantía es válida por 1 año 12 meses a partir de la fecha de compra Si estos productos fallan durante el periodo del año de garantía debido a un defecto en los materiales o la maniobra a elección de la empresa la empresa o el distribuidor s...

Page 15: ...IEC 61000 3 2 No se aplica Fluctuaciones de voltaje emisiones de parpadeo IEC 61000 3 3 No se aplica Dirección y la declaración del fabricante inmunidad electromagnética Los WiTouch y WiTouch Pro son intentado para el uso en un ambiente electromagnético especificado abajo El cliente o el usuario del WiTouch o WiTouch Pro deberían asegurar que es usado en tal ambiente Prueba de inmunidad IEC 60601 ...

Page 16: ...propagación electromagnética es afectada por absorción y reflexión de estructuras objetos y personas Dirección y la declaración del fabricante inmunidad electromagnética Los WiTouch y WiTouch Pro son intentado para el uso en un ambiente electromagnético especificado abajo El cliente o el usuario del WiTouch o WiTouch Pro debe usarse en este tipo de ambiente Prueba de inmunidad IEC 60601 Nivel de p...

Reviews: