B U L L E T I N
G L V - 4 0 S 1 # 1 1 9 6 G E A R L E S S T R A C T I O N M A C H I N E
Page 5-3
Rev. A - 04/01/2022
•
Connect the U-V-W lines from the drive as shown.
•
Earth Ground connects to the ground lug terminal inside the electrical enclosure.
Note - Check and tighten all leads (motor side and line side) on installation.
WARNING
The machine and emergency brake coils must be independent!
It is the responsibility of the user to connect the motor in accordance
with the current laws and regulations in the country of use. This is
particularly important regarding wire sizes used to connect the
power, earth ground, and the type and size of fuses.
CONTROLLER
CONNECTIONS
TPS
CONNECTIONS
Figure 7