![Holiday Admiral 2016 Manual Download Page 141](http://html1.mh-extra.com/html/holiday/admiral-2016/admiral-2016_manual_2145196141.webp)
139
house ele
C
tr
IC
al - 8
2016 Admiral
Maintenance:
Kinks may form in the shore power cord.
Routinely extend the cord full length and
straighten the cord.
Power Supply:
The continuous amount of current
z
through a breaker or fuse is 80% of its
rated capacity. A 30 Amp shore power
connnection is limited to 24 continuous
amps.
Use care when hooked to anything
z
less than 30 Amp shore service. 20
Amp shore service is limited to 16
continuous amps.
Electrical Adapters:
Another common adapter is a 30 to 20 Amp
adapter. This type of connector adapts the 30
Amp shore cord to a 20 Amp shore power
outlet.
CAUTION:
If shore power service is limited to 15
or 20 amps, use of light duty extension
cords and electrical adapters will
create a voltage loss through the cord
and at each electrical connection.
Line voltage loss and the resistance
at each electrical connection can be a
hazardous combination. Damage to
sensitive electronic equipment may
result!
WARNING:
Avoid the risk of electrical shock or
component damage by disconnecting
from shore power during electrical
storm activity. Start the generator if
AC power is needed.
NOTE:
Three types of shore power outlets
most commonly used are shown in the
illustration.
WARNING:
Disconnect from shore power before
working on the electrical system.
Disconnect the negative 12 Volt DC
battery cables at the batteries. Remove
rings, metal watchbands and other
metal jewelry before working around
batteries and connectors. Use caution
when working with metal tools. If the
tool contacts a battery terminal or
metal connected to it, a short circuit
could occur causing personal injury,
explosion or fire.
gENERATOR - 120 vOLT Ac
The generator output is 4.0Kw. The generator
can be started from the following locations:
Generator remote start on the monitor
z
panel.
Generator control panel located on the
z
generator.
INFORMATION:
Refer to the generator OEM manual
for detailed operating instructions and
information.
Requirement for Operation:
House battery disconnect switch must
z
be On.
Starting the Generator
Prior to starting the generator, perform a
general inspection including oil and coolant
levels. Keep a maintenance log on number
of hours of operation since the last service.
Perform any service or maintenance that may
be due.
Before Starting the Generator:
Clear people and pets from potential
z
of an electrical shock and any moving
parts.
All appliances and other large AC
z
electrical loads should be turned off
prior to starting the generator.
Push and hold the control switch to
z
Start. Release the switch when the
generator starts.
060174
Typical 30 - 20 Amp adapter
060121c
060337
It is recommnded to use a surge protector to
protect voltage sensitive equipment.
Summary of Contents for Admiral 2016
Page 10: ...Notes...
Page 50: ...48 Dri v i ng s a f ety 2 2016 Admiral Notes...
Page 110: ...108 e q u i p m e n t 5 2016 Admiral Entertainment Wiring...
Page 124: ...122 Water Systems 6 2016 Admiral Notes...
Page 136: ...134 Pro pan e S y s tems 7 2016 Admiral Notes...
Page 152: ...150 h o u s e e l e c t r ic a l 8 2016 Admiral Notes...
Page 156: ...154 s PE C I F I C AT I ONS 9 2016 Admiral Weight Record Sheet...
Page 158: ...156 s PE C I F I C AT I ONS 9 2016 Admiral Notes...
Page 162: ...160 Ind e x 2016 Admiral Notes...