Water Systems
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
2 0 0 2 N E P T U N E
6 • 187
Vibration induced by road conditions can cause the plumbing or pump hard-
ware to loosen. Check for system components that are loose. Many symptoms can
be resolved by tightening the hardware. Check the following items:
The water pump will not start/blows the fuse:
• Check the electrical connections, fuse, breaker, main switch and
ground connection.
• Is the motor hot? The thermal breaker may have triggered. It will reset
when cool.
• Is the voltage present at the switch? Bypass the pressure switch.
• Does the pump operate? Check the charging system for correct voltage
and check the pump for the proper ground connection.
• Look for an open or grounded circuit or motor.
• Check for seized or locked diaphragm assembly (water frozen).
The water pump will not prime/sputters: (No discharge/motor runs):
• Is the strainer clogged with debris?
• Is there water in the tank or has air collected in the hot water heater?
• Is the inlet tubing/plumbing sucking in air at plumbing connections
(vacuum leak)?
• Check for proper voltage with the pump operating.
• Look for debris in the pump inlet/outlet valves or dry/swollen valves.
• Check the pump housing for cracks or loose drive assembly screws.
The water pump will not shut-off/runs when the faucet is closed:
• Check to see if the fresh water tank fill valve is completely closed.
• Check output side (pressure) plumbing for leaks and inspect for a
leaky toilet or valves.
• Look for loose drive assembly or pump head screws.
• Are the valves or the internal check valve held open by debris or is
the rubber swollen?
The water pump is noisy or rough in operation:
• Check for plumbing which may have vibrated loose.
• Does the mounting surface multiply noise (flexible)?
• Check for mounting feet that are loose or compressed too tight.
• Look for loose pump head to motor screws.
The water pump is rapid cycling:
• Look for restrictive plumbing/flow restrictors in the faucets or
shower heads.
Water Pump -
Troubleshooting
Summary of Contents for 2002 NEPTUNE
Page 12: ......
Page 28: ...General Information 2 0 0 2 N E P T U N E 1 28 NOTES...
Page 32: ......
Page 73: ...Driving Safety 2 0 0 2 N E P T U N E 2 73 Rear View VIEWS Front View OM010726 OM010725...
Page 74: ...Driving Safety 2 0 0 2 N E P T U N E 2 74 Curbside View Roadside View OM010724 OM010723...
Page 82: ......
Page 116: ......
Page 154: ......
Page 182: ......
Page 202: ...Water Systems 2 0 0 2 N E P T U N E 6 202 NOTES...
Page 204: ......
Page 218: ...LP Gas System 2 0 0 2 N E P T U N E 7 218 NOTES...
Page 220: ......
Page 256: ......
Page 279: ...Electrical Systems Chassis 2 0 0 2 N E P T U N E 9 279 NOTES...
Page 280: ...Electrical Systems Chassis 2 0 0 2 N E P T U N E 9 280 NOTES...
Page 282: ......
Page 331: ...Chassis Information 2 0 0 2 N E P T U N E 10 331 MAINTENANCE RECORD...
Page 332: ...Chassis Information 2 0 0 2 N E P T U N E 10 332 MAINTENANCE RECORD...
Page 333: ...Chassis Information 2 0 0 2 N E P T U N E 10 333 MAINTENANCE RECORD...
Page 336: ......
Page 337: ...INDEX...
Page 338: ......