![Hoffer Flow Controls HIT-4L User Manual Download Page 44](http://html1.mh-extra.com/html/hoffer-flow-controls/hit-4l/hit-4l_user-manual_2144088044.webp)
38 Modbus Communications
HP-329
HIT-4L
Register
(Decimal)
Description
Data
Type
Access
Notes
700
Request Hourly
Logs
FP32
(4)
RO
701
Request Daily
Logs
FP32
(4)
RO
1002
Software Version
FP32
RO
1003
Device Type
U16
RO
0=4U, 1=4G, 2=4L
1005
Turbine Serial
Number
U32
R/W 1 – 99999999
1006
Electronic ID
Number
U32
R/W 1 – 99999999
1007
Password
U16
R/W 0000-9999
1008
Lock Unit
U16
R/W 0=No, 1=Yes
1009
Slave Address
U16
R/W 0-253
1010
Baud Rate
U16
R/W 0 = 9600, 1 = 57000, 2
= 115200
1011
Sample Time
U16
R/W 1-80
1013
Contract Hour
U16
R/W 1-24
1200
Year
U16
R/W 0-99
1201
Month
U16
R/W 1-12
1202
Day
U16
R/W 1-31
1203
Hour
U16
R/W 1-24
1204
Minute
U16
R/W 0-59
1205
Second
U16
R/W 0-59
2000
Total Units
U16
R/W 0=gal, 1=bbl, 2=L, 3=lb,
4=kg, 5=acf,
6=acfx1000, 7=scf,
8=scfx1000, 9=m3,
10=nm3
2001
Total Decimal
Point
U16
R/W 0-3
2003
Rate Time Base
U16
R/W 0=sec, 1=min, 2=hr,
3=day
2004
Rate Decimal
Point
U16
R/W 0-3
Summary of Contents for HIT-4L
Page 2: ......
Page 30: ...24 Installation HP 329 HIT 4L This page intentionally left blank...
Page 42: ...Operation 36 HP 329 HIT 4L This page intentionally left blank...
Page 52: ...HIT 4 Communication Program 46 HP 329 HIT 4L This page intentionally left blank...
Page 68: ...62 HIT 4 Communication Program HP 329 HIT 4L This page intentionally left blank...
Page 71: ...Appendix A Declaration of Conformity 65 HIT 4L HP 329 APPENDIX A DECLARATION OF CONFORMITY...
Page 72: ...66 Appendix A Declaration of Conformity HP 329 HIT 4L...