Safety valve for boiler (Frost Control)
Hot air valve
To activate
• Push in the knob at position (
m
) slightly and, at the same
time, move it 90° towards position (
k
).
• If the switch is in position (k), the knob will remain in position (
m
).
To deactivate
• Turn the switch at position (
k)
by 90° so that it is parallel to
the frost control.
• At the same time, the knob will jump from position (
m
) to (
n
).
The drain valve can only be closed manually using the
push button (Position
m
) and the boiler filled if the valve
temperature is above approx. 7°C.
If the temperature of the safety/drain valve is lower than approx.
3°C, the push button will be ejected (Position
n
) and the con-
tents of the boiler will be drained off via the drain outlet (
o
).
Hot air valve in alcove
The alcove models are equipped with hot air vents in the
alcove bed. The slider
j
is used to regulate the amount of
hot air.
Depending on the model, the hot air slider is located either
on the standing wall of the kitchen unit in the direction of the
passenger seat or in the seating arrangement on the side wall
towards the rear of the mobile home.