5-3. Process/Polarity Table
Process
Polarity
Cable Connections
Process
Polarity
Cable To Gun
Cable To Work
GMAW
−
Solid wire with shield-
ing gas
DCEP
−
Reverse polarity
Connect to positive (+) out-
put terminal
Connect to negative (
−
) output
terminal
FCAW
−
Self-shielding wire
−
no shielding gas
DCEN
−
Straight Polarity
Connect to negative (
−
)
output terminal
Connect to positive (+) output
terminal
CHANGING
POLARITY
5-4. Changing Polarity
1
Lead Connections For Direct
Current Electrode Negative
(DCEN)
2
Lead Connections For Direct
Current Electrode Positive
(DCEP)
Always read and follow wire
manufacturer’s recommended
polarity, and see Section 5-3.
Close door.
Ref. 209 228 / Ref. 209 229
1
2
DCEN
Electrode negative for
flux cored wire
DCEP
Electrode positive for
solid wire