OM-925 Page 32
9-2.
Typical MIG Process Control Settings
These settings are guidelines only. Material and wire type, joint design, fitup,
position, shielding gas, etc. affect settings. Test welds to be sure they comply to
specifications.
NOTE
3.5 x 125 A = 437 ipm
2 x 125 A = 250 ipm
1.6 x 125 A = 200 ipm
30
−
90 A
40
−
145 A
50
−
180 A
Convert Material
Thickness to
Amperage (A)
Material thickness determines weld
parameters.
.035 in
Recommendation
Wire Speed
(Approx.)
1/8 or 0.125 in
(0.001 in = 1 ampere)
0.125 in = 125 A
Wire Size
Amperage Range
0.023 in
0.030 in
0.035 in
Select Wire Size
Wire
Size
0.023 in
0.030 in
0.035 in
3.5 in per ampere
2 in per ampere
1.6 in per ampere
Select Wire Speed
(Amperage)
125 A based on 1/8 in
material thickness
ipm = inches per minute
Low voltage: wire stubs into work
High voltage: arc is unstable (spatter)
Set voltage midway between high/low voltage
Select Voltage
Ref. 803 710-A
Voltage controls height
and width of weld bead.
Wire speed (amperage) controls weld
penetration (wire speed = burn-off rate)
Summary of Contents for H-10 Gun
Page 24: ...OM 925 Page 20 6 2 Weld Parameter Chart For 115 VAC Model ...
Page 25: ...OM 925 Page 21 217 618 A ...
Page 26: ...OM 925 Page 22 6 3 Weld Parameter Chart For 230 VAC Model ...
Page 27: ...OM 925 Page 23 217 754 B ...
Page 34: ...OM 925 Page 30 217 755 A Figure 8 2 Circuit Diagram For 230 VAC Model ...
Page 45: ...OM 925 Page 41 Notes ...