OM-925 Page 39
9-16. Common MIG Shielding Gases
This is a general chart for common gases and where they are used. Many different combinations (mixtures) of
shielding gases have been developed over the years. The most commonly used shielding gases are listed in the
following table.
Application
Gas
Spray Arc Steel
Short Circuiting Steel
Short Circuiting
Stainless Steel
Aluminum
Argon
X
Argon + 25% CO
2
X
80% or greater Argon +
balance CO
2
or Oxygen
X
X
1
100% CO
2
X
Tri-Mix
2
X
1
Limited short circuiting use
2
90% HE + 7-1/2% AR + 2-1/2% CO
2
9-17. Troubleshooting Guide For Semiautomatic Welding Equipment
Problem
Probable Cause
Remedy
Wire feed motor operates, but
wire does not feed
Too little pressure on wire feed rolls.
Increase pressure setting on wire feed rolls.
wire does not feed.
Incorrect wire feed rolls.
Check size stamped on wire feed rolls, replace to match
wire size and type if necessary.
Wire spool brake pressure too high.
Decrease brake pressure on wire spool.
Restriction in the gun and/or assembly.
Check and replace cable, gun, and contact tip if
damaged. Check size of contact tip and cable liner,
replace if necessary.
Wire curling up in front of the
wire feed rolls (bird nesting)
Too much pressure on wire feed rolls.
Decrease pressure setting on wire feed rolls.
wire feed rolls (bird nesting).
Incorrect cable liner or gun contact tip size.
Check size of contact tip and check cable liner length
and diameter, replace if necessary.
Gun end not inserted into drive housing properly.
Loosen gun securing bolt in drive housing and push gun
end into housing just enough so it does not touch wire
feed rolls.
Dirty or damaged (kinked) liner.
Replace liner.
Wire feeds, but no gas flows. Gas cylinder empty.
Replace empty gas cylinder.
Gas nozzle plugged.
Clean or replace gas nozzle.
Gas cylinder valve not open or flowmeter not adjusted. Open gas valve at cylinder and adjust flow rate.
Restriction in gas line.
Check gas hose between flowmeter and wire feeder, and
gas hose in gun and cable assembly.
Loose or broken wires to gas solenoid.
Have Factory Authorized Service Agent repair wiring.
Gas solenoid valve not operating.
Have Factory Authorized Service Agent replace gas
solenoid valve.
Incorrect primary voltage connected to welding power
source.
Check primary voltage and relink welding power source
for correct voltage.
Summary of Contents for H-10 Gun
Page 24: ...OM 925 Page 20 6 2 Weld Parameter Chart For 115 VAC Model ...
Page 25: ...OM 925 Page 21 217 618 A ...
Page 26: ...OM 925 Page 22 6 3 Weld Parameter Chart For 230 VAC Model ...
Page 27: ...OM 925 Page 23 217 754 B ...
Page 34: ...OM 925 Page 30 217 755 A Figure 8 2 Circuit Diagram For 230 VAC Model ...
Page 45: ...OM 925 Page 41 Notes ...