7 Start up / Shut down
Operation manual mzr-2509 Ex/ mzr-2909 Ex / mzr-4609 Ex / mzr-7209 Ex
56
Technische Änderungen ohne Vorankündigung vorbehalten
Last update: October 2016
7.7.1
Conservation
If the micro annular gear pump operates at irregular intervals or for other
reasons should be put out of operation for a longer period, it should, after
service and flushing procedure (see chapter 7.6), be filled in with a suitable
conservation liquid.
The conservation liquid may be selected from the table 23 depending on the
duration of the standstill and the resistance of the pump to the manipulated
liquid. The indicated conservation liquids are simple recommendations
and
should therefore be checked by the user as to their compatibility and suitability
.
The figure 21 presents a diagram of conservation agent selection.
Remark
: This diagram is repeated as a part of the figure 20 (shutdown
procedure of the micro annular gear pump).
After the cleansing procedure the pump should be filled with a suitable
conservation agent. You will find a choice of possible conservation agents in
the table 23.
Selection of conservation
liquid (CL)
CL
adequate
Is the CL
compatible
with pump
Is the CL
compatible
with the
last FL ?
yes
no
no
no
yes
yes
End of CL
selection
figure 27
Diagram - selection of conservation liquid (CL)
see table 22 (Resistance of the sealing material)
see table 23 (Selection of the conservation agent)