5 Modular system
Operation manual mzr-2509 Ex/ mzr-2909 Ex / mzr-4609 Ex / mzr-7209 Ex
30
Technische Änderungen ohne Vorankündigung vorbehalten
Last update: October 2016
Thermal element
IEC 584.3
identification
Type
Thermocoax:
4ABAo15/35mm/TI/D5
0/4ABAB40T/12m –
ATEX EExia IIC T6
_
+
+
_
Thermal element
2 Thermal elements
Typ K (NiCr-Ni;
Chromel-Alumel)
Temperature measuring range
-100 to +400 °C
(-148 to 752 °F)
Diameter of the sensing device approx. 1.5 mm
Material
V4A (1.4541)
Length compensating circuit
12 m
Diameter compensating circuit 4 mm
Double jacket
mzr-2909 Ex
mzr-4609 Ex
mzr-7209 Ex
Length
34.25 mm
37.0 mm
37.5 mm
Diameter
42.4 mm
42.4 mm
48.3 mm
Double jacket material
stainless steel 316L
stainless steel 316L
stainless steel 316L
Inlet
2xG1/8“ (45°
distance)
2xG1/8“ (45° distance) 2xG1/8“ (45° distance)
Operating temperature range
-20 to +150 °C
(-4 to +266 °F)
-20 to +150 °C
(-4 to +266 °F)
-20 to +150 °C
(-4 to +266 °F)
Max. pressure
max. 20 bar
max. 20 bar
max. 20 bar
Flow rate
max. 0.5 l/min
max. 0.5 l/min
max. 0.5 l/min
table 12
Technical data of the heating and cooling module
The pump carries the changed identification with the non insulating coupling
components and the higher temperature:
CE
II 2G c IIC T3 X
Description of the single symbols:
Equipment meets the requirements of the RL 94/9/EG
II
Equipment of the group of equipment II („Non-mining industry“)
2G
Equipment of the category 2, intended for the employment in zone
1 (explosion endangerment by inflammable gases, steams or
nebulas), can be used also in zone 2
c
As explosion prevention measure the ignition enclosure was
converted „constructional security“(c) according to EN 13463-5.
IIC
The equipment fulfills the requirements for the employment within
highly combustible ranges, within which the explosion
endangerment can be due to materials of the explosion group IIC
(like e.g. hydrocarbons).