2.
Activate one of the following Easy Config Modes:
Figure 7. Easy Config modes menu
• Easy Config Mode 1 for Bluetooth PANU-PANU. Used for setting up point-to-point
communication.
• Easy Config Mode 5 for WLAN.
• Easy Config Mode 6 for Bluetooth.
3.
Connect Client 1 to power.
4.
Automatic configuration of the units starts:
• Client 1 starts up in Easy Config Mode 4 and is open for automatic configuration
during 120 seconds.
• Access Point 2 will discover and configure Client 1 as a Client and configure itself as
an Access Point.
• Client 1 will be assigned the first free IP address in the same Ethernet subnet as
Access Point 2.
The default address to Client 1 is 192.168.0.100.
Troubleshooting if no connection is established during Easy Config Mode
• Ensure that Client 1 is disconnected from Ethernet.
• Disconnect Client 1 from power and repeat the steps to activate Easy Config.
Add Additional Bolt Serial Clients
Option when using Easy Config Mode 1: Continue with the configuration, see
.
Set Up Wireless Infrastructure
Anybus
®