5.4. Available Easy Config Modes
Bolt Serial may be configured using one of the pre-configured Easy Config modes.
NOTE
By default, the unit starts in Easy Config Mode 4. The unit awaits
automatic configuration during 120 seconds or until receiving a
configuration.
NOTE
To cancel Easy Config mode 11, the unit must be reset to factory default
settings. See
Table 1. Easy Config modes
EC
Role
Description
1
Bluetooth
PANU
Used for setting up point-to-point communication.
The unit scans for another unit in Config Mode 4. The unit listens for 40 seconds or until a
configuration is established.
When a unit in mode 4 is detected: The scanning unit configures itself as a Bluetooth PANU
Client, sends a connection configuration to the detected unit, and restarts. The detected unit
restarts and attempt to connect to the first unit as a PANU Client.
2
N/A
Reset configuration to factory defaults.
3
N/A
Reset IP settings to factory defaults.
4
Client
Configure units in mode 4 as Clients.
Wait for automatic configuration. The unit listens for 120 seconds or until receiving a
configuration.
When mode 4 is used with mode 1, 5 or 6, Serial Settings TCP Mode Client is activated
automatically.
5
WLAN AP
The unit scans for other units in Config Mode 4 and configure them as Clients. Timeout occur
after 120 seconds.
Restart as Access Point and connect Clients.
6
Bluetooth
NAP
11
(any)
Enable PROFIsafe mode. The unit is locked in PROFIsafe mode.
No other configuration settings are changed.
Anybus
®
Wireless Bolt Serial
™
Available Easy Config Modes