2. Safety
2.1. General Safety
CAUTION
This equipment emits RF energy in the ISM (Industrial, Scientific, Medical)
band. Make sure that all medical devices used in proximity to this
equipment meet appropriate susceptibility specifications for this type of
RF energy.
CAUTION
This equipment contains parts that can be damaged by electrostatic
discharge (ESD). Use ESD prevention measures to avoid damage.
CAUTION
Minimum temperature rating of the cable to be connected to the field
wiring terminals, 90 °C.
CAUTION
Use copper wire only for field wiring terminals.
CAUTION
This equipment is recommended for use in both industrial and domestic
environments. For industrial environments it is mandatory to use the
functional earth connection to comply with immunity requirements. For
domestic environments the functional earth must be used if a shielded
Ethernet cable is used, in order to meet emission requirements.
Safety
Anybus
®
Wireless Bolt Serial
™
SP2554 2.0
Page 3 of 28