Scanreco G2 radio remote control system
52
HMF Technical Service Department
Rev.:
20-13
Error codes
Comment
RCL
display
LED display
in G2
Error code in
the RCL
5300 black
box
Error
description
Cause
Remedy
176
17.01
1701
The power
supply is too low.
The power supply is
below 9 VDC.
The system carries out
automatic reset.
Check the power supply
and the cable connections
and the plug and socket-
outlets.
177
17.02
1702
The power
supply is too
high.
The power supply
exceeds 36 VDC.
The system carries out
automatic reset.
Check the power supply
and the cable connections
and the plug and socket-
outlets.
174
98.00
9800
There is a
general failure in
the remote
control box.
There is an
undefinable failure in
the remote control
box.
Troubleshoot with the
remote control box in
TEST MODE.
170
99.00
9900
There is a
general failure in
the radio
controller.
There is an
undefinable failure in
the radio controller.
The system carries out
automatic reset. Dismount
all plug and socket-outlets
in the radio controller.
Check the power supply
and the cable connections
and the plug and socket-
outlets.