Scanreco G2 radio remote control system
21
HMF Technical Service Department
Rev.:
20-13
Signal name
Signal source
Description of signal
RC But 16 (OPT 5)
Activation of the ON push button.
In the default settings the signal is used for
starting up the remote control box.
RC But 17 (OPT 6)
Reserved
No signal has been defined.
RC But 18 (DIS SEL)
Activation of tumbler switch no. 10
and the yellow push button (pos. 7).
When activating the yellow press button
several times, you change between the
screens of the remote control box.
RC But 19 (OPT 7)
Activation of tumbler switch no. 10
and tumbler switch no. 2 - to the left
(spring return).
Extra available digital signal for an extra
function.
RC But 20 (OPT 8)
Activation of tumbler switch no. 10
and tumbler switch no. 2 - to the
right (spring return).
Extra available digital signal for an extra
function.
RC But 21 (REGEN)
Activation of the ON push button.
In the default settings the signal is used for
activating the regeneration function.
RC But 22 (STAB)
Activation of tumbler switch no. 2 -
to the left.
In the default settings the signal is used as
an extra activation with holding function
(safety function), when operating stabilizers
in stabilizer mode.
RC But 23 (OPT 9)
Activation of tumbler switch no. 4 -
to the left.
Extra available digital signal for an extra
function (option)
RC But 24 (OPT 10)
Activation of tumbler switch no. 4 -
to the right.
Extra available digital signal for an extra
function (option)
RC But 25 (OPT 11)
Activation of tumbler switch no. 5 -
to the left.
Extra available digital signal for an extra
function (option)
RC But 26 (OPT 12)
Activation of tumbler switch no. 5 -
to the right.
Extra available digital signal for an extra
function (option)
RC But 27 (OPT 13)
Activation of tumbler switch no. 9 -
to the left.
Extra available digital signal for an extra
function (option)
RC But 28 (OPT 14)
Activation of tumbler switch no. 9 -
to the right.
Extra available digital signal for an extra
function (option)
Slew
Activation of a remote control lever. Proportional signal for the crane function –
"Slew".
Boom
Activation of a remote control lever. Proportional signal for the crane function –
"Boom".
Jib
Activation of a remote control lever. Proportional signal for the crane function –
"Jib".
Extension
Activation of a remote control lever. Proportional signal for the crane function –
"Extension".
Flyjib
Activation of a remote control lever. Proportional signal for the crane function –
"Fly-Jib - jib".
Flyjib Ext.
Activation of a remote control lever. Proportional signal for the crane function –
"Fly-Jib - extension".
Winch
Activation of a remote control lever. Proportional signal for the crane function –
"Winch".
Rotator
Activation of a remote control lever. Proportional signal for the crane function –
"Rotator".
Grab
Activation of a remote control lever. Proportional signal for the crane function –
"Grab".
Aux1
Activation of a remote control lever. Proportional signal for a first extra control
valve function.
Aux2
Activation of a remote control lever. Proportional signal for a second extra
control valve function.
Aux3
Activation of a remote control lever. Proportional signal for a third extra control
valve function.
Aux4
Activation of a remote control lever. Proportional signal for a fourth extra control
valve function.