Scanreco G2 radio remote control system
30
HMF Technical Service Department
Rev.:
20-13
Set-up and connection of engine control functions
In the table below is indicated an example of the standard set-up of the engine control functions.
The engine control functions are activated by the tumbler switches 1, 2 and 3 on the remote
control box. When operating an engine function, the configured output terminals in the K4 socket
in the radio controller receive a high signal, which continues onto the conductors of the EX1
cable.
Please also see the detailed description of the engine control functions in the chapter "Setting up
of output signals by means of the CGW 5355" as well as the electric diagrams: IRC, G2 or
NEMRC, G2.
The RCL 5300 software must be version 29_20 or higher.
Menu item in CGW 5355
Configuration
Description of the function
1.1.1.1.3.25 - PWM Mixer
Press ENT
- Activate the feature
PWM Mixer.
1.1.1.1.1.25 - PWM Mixer
ENT
- Setting up in
PWM Mixer
.
1.1.1.1.1.25.1 - Digital
ENT
- Setting up of digital outputs.
1.1.1.1.1.25.1.1 - K4.1
SET, arrow down - Signal on the output terminal K4.1 for increasing the
number of revolutions when operating a crane
function:
select
ENGINE FULL
1.1.1.1.1.25.1.2 - K4.2
SET, arrow down - Signal on the output terminal K4.2 for starting up
the engine:
select
ENGINE START
1.1.1.1.1.25.1.3 - K4.3
SET, arrow down - Signal on the output terminal K4.3 for stopping the
engine:
select
ENGINE STOP
1.1.1.1.1.25.1.4 - K4.4
SET, arrow down - Signal on the output terminal K4.4 for increasing the
number of revolutions of the engine by each
activation of the tumbler switch no. 3 to the left: select
ENGINE RPM P
1.1.1.1.1.25.1.5 - K4.5
SET, arrow down - Signal on the output terminal K4.5 for reducing the
number of revolutions of the engine by each
activation of the tumbler switch no. 3 to the right:
select
ENGINE RPM M