![HMF Scanreco G2 Manual Download Page 46](http://html1.mh-extra.com/html/hmf/scanreco-g2/scanreco-g2_manual_2141494046.webp)
Scanreco G2 radio remote control system
46
HMF Technical Service Department
Rev.:
20-13
The LED display shows the value for the adjustment and the output terminal in question.
Example: ”
2A
” - ”
20
”
- 2A is the output terminal
- 20 is the current intensity in percent.
To get out of the online programming mode, push the red stop button.
Self-test mode
In connection with service and troubleshooting, it is possible to put the remote control box in self-
test mode. All push buttons, tumbler switches and remote control levers can be tested without
having to disassemble the remote control box.
Procedure for testing
1. Push the stop button.
2. Turn/pull out the stop button again.
3. Activate the ON push button a couple of seconds; the red Power LED is constantly lit.
4. Push the ON button approx. 10 times in rapid succession until the Power LED is flashing.
5. When pushing a push button or activating a tumbler switch, the buzzer must give a signal,
thereby confirming a correct activation.
6. When activating a remote control lever, the buzzer must give a signal that increases in
intensity the more the remote control lever is activated. When the remote control lever is
completely activated, the buzzer gives a constant signal.
To get out of the self-test mode, push the red stop button.
If there is no signal when operating in self-test mode, it may be due to an error in the remote
control lever/push button/tumbler switch, in the plug and socket-outlet or in the printed circuit
board.