Model kotła
Parametr
Jednostka
HM 20
Required chimney draught
Pa / mbar
5 ÷ 15 / 0,05 ÷ 0,15
Required chimney diameter
mm
160 ÷ 180
Average exhaust temperature at nominal
output
0
C
140
Maximum temperature of the boiler
0
C
80
Recommended temperature of the boiler
0
C
70 ÷ 80
Minimum temperature of the returning water
0
C
65
Exhaust flow at the nominal output
g/s
15
CO emission at the nominal output (10% O
2
)
mg/m
3
300
CO emission at the nominal output (13% O
2
)
mg/m
3
220
Noise level
dB
below 75
Electricity plug-in
1 PEN ~50Hz 230V TN-S
Electric insulation
IP 20
Electric power consumption (exhaust fans)
W
75
Ambient temperature
0
C
15 ÷ 40
Humidity
%
10 ÷ 90%
without condensation
Capasity of loading chamber
dm
3
125
Exhaust fan
model
R2E180-CG82 / WC.170
Table 2. Holz Master boiler specifications
Holz Master Manual
wer. 22/05/2012/EN/V1.0
HKS LAZAR
str.7