20
MM06UE01-2002
Connect positioning measurement system cable (see Section 5.3.2).
Switch on the controller.
Check the positioning measurement system (see separate assembly instructions for the drive and positioning
measurement system).
Switch off the controller.
Connect the motor cable (see Sections 5.3.1).
Switch on the controller.
Perform test run at slow speed.
Perform test under usage conditions.
6.2 Programming
The programming of the linear motor system depends on the controller and drive used. Observe the user
manual for the controller and drive!