12
MM06UE01-2002
Fig. 4.2 lifting example – here for a LMSSA linear motor system(long stroke)
4.3 Requirements at the installation site
4.3.1 Ambient conditions
Table 4.1
Ambient condition requirement
Area of use
For indoor use only
Temperature
0 °C to 50 °C
Humidity
< 80%RH (non-condensing)
Altitude
< 1000 m
Installation site
Flat, dry, vibration-free
Protection class
IP50 and no interference from corrosive solvent or strong magnetic
Grounding
Plant power grounding line conforms to international requirements
Avoid exposing to direct sunlight or hear rays.
Away from electric magnetic interference source sites, such as welding, discharge machine.
4.3.2 Safety equipment to be provided by the operator
Possible safety equipment/measures:
●
Personal protective equipment in accordance with regional regulations
●
Zero-contact protective equipment
●
Mechanical protective equipment
4.4 Storage
DANGER!
Danger from strong magnetic fields!
Strong magnetic fields around linear motor systems pose a health risk to persons with implants
(e.g. cardiac pacemakers) that are affected by magnetic fields.
Persons with implants that are affected by magnetic fields should maintain a safe distance of at
least 1 m from linear motor systems.
Store the linear motor system in its transport packaging.
Only store the linear motor system in dry, frost-free areas with a corrosion-free atmosphere.
Clean and protect used linear motor system before storage.