Assembly and connection
47
Assembly Instructions
Linear Axes HM-S and HT-S
HMS_HTS-01-0-EN-1905-MA
HT150S/HT200S:
Tighten the bolt on the clamping hub. See Table 6.16 for the tightening torque.
HT100S/HT250S:
First, place the screw on the 1st side on the clamping hub, then tighten the screw on the 2nd side and after that on the
1st side with the tightening torque shown in Table 6.16.
Depress the elastomer insert into the clamping hub.
Fig. 6.43
Tightening the clamping hub and depressing the elastomer insert (HT150S, HT200S)
Fig. 6.44
Mounting the clamping hub and the coupling housing KB on the HT-S linear table
L
1
Using four bolts, mount the coupling housing KB so that it lies flat. See Table 6.17 for the tightening torques.
Push the clamping hub onto the elastomer insert until measurement L
1
(see Table 6.18) has been achieved.
The elastomer insert must be lightly preloaded and should have no backlash. A small quantity of PU compatible
grease can be applied to the elastomer insert for easier installation.
NOTE
Axis type
Coupling size
L
1
[mm]
HT100S
14
10.0
HT150S
19
14.0
HT200S
19
14.0
HT250S
24
16.5
Table 6.18
Adjusting the coupling distance based on measurement L
1
Summary of Contents for HM-S
Page 99: ......