background image

 

 

 

II. Flue Systems 

 

A good chimney is essential. This room heater must be connected to (1) a listed Type HT 
(2100°F) chimney per UL 103 or ULC S629, or (2) a code-approved masonry chimney with a flue 
liner. 

Masonry Flue System:

 It is important to make sure that the masonry chimney is structurally 

sound and on a solid foundation. The masonry chimney must have a liner installed within the 
chimney construction.  An unlined chimney is not safe with solid fuel systems, and may result in a 
house fire. The liner may be constructed with a structurally sound clay liner or a stainless steel 
liner.  If using an existing masonry chimney, be sure to have the chimney examined and cleaned 
by a chimney professional.  The structural foundation of the chimney and liner is important.  If 
existing clay liner is cracked or damaged, it is recommended to re-line the chimney with a 
stainless steel liner.  Be sure the masonry chimney is compatible with the local building codes and 
requirements.

 

 

Factory Built System: 

The factory built chimney must be a listed Type HT (2100°F) chimney per 

UL 103 or ULC S629. If using an existing factory built Class A chimney it must be inspected and 
cleaned by a certified chimney professional, before use. With Factory Built Chimneys the chimney 
manufacturer’s clearances and distance requirements must be followed. It is also important to 
abide by the rules and regulations of local jurisdictions upon chimney installation.  
 

 

 

THE DIAGRAMS ARE FOR INFORMATIONAL PURPOSES ONLY. FOLLOW CHIMNEY 

MANUFACTURER’S INSTALLATION INSTRUCTIONS. 

Summary of Contents for 55 FA

Page 1: ...DAMAGE PERSONAL INJURY OR DEATH FURNACE SURFACES MAY BECOME HOT WHILE IN OPERATION HIGH FURNACE TEMPERATURES MAY IGNITE CLOTHING OR FLAMMABLE MATERIAL FOR USE OF SOLID FUEL COAL ONLY OTHER FUEL SOURC...

Page 2: ...FM output of each furnace You can then get an idea if the ductwork is sized such that the operating static pressure of the two combined will not go over the maximum for either if both operate at the s...

Page 3: ...d by a chimney professional The structural foundation of the chimney and liner is important If existing clay liner is cracked or damaged it is recommended to re line the chimney with a stainless steel...

Page 4: ...urnace should be a minimum of 7 inches in diameter Flue Size Continued The flue size also has a maximum size of inches in order to sustain the desired draft For an interior chimney the flue and chimne...

Page 5: ...FOR SOLID FUEL VENTING IS UNSAFE AND PROHIBITED BY THE NATIONAL FIRE PROTECTION ASSOCIATION CODE III Location of Furnace and Installation WARNING THE INSTALLATION OF THESE STOVES MUST COMPLY WITH STA...

Page 6: ...ng concealed spaces or enter the chimney in the attic If connection is made through a combustible wall a listed and approved wall thimble pass through must be used following the manufacturer s instruc...

Page 7: ...all or Ceiling 18 Unit must be placed on a noncombustible floor Hot Air Supply Duct Hookup With the furnace now in place and the flue connector connected to the chimney it is time to connect the suppl...

Page 8: ...ill greatly improve the air movement up through the system There are also cover plates along both sides at the bottom of the furnace These can also be removed during a power outage to increase the nat...

Page 9: ...ation formats Note these illustrations reflect typical installations and are for design purposes only Illustrations and diagrams are for informational purposes only These diagrams are not drawn to sca...

Page 10: ......

Page 11: ...to operate other than as intended Do not have hot air from gas or oil furnace flow downward into the Hitzer Furnace and flow out the Hitzer Furnace to existing duct work IV Operation Of Furnace WARNI...

Page 12: ...y load the stove to maximum heating potential Starting An Anthracite Coal Fire Starting an Anthracite coal fire takes time and patience Take several sheets of newspaper crumble into balls and place on...

Page 13: ...t air flow and the ability of the coal to burn When this happens this block of burning coal must be broken up with a poker to restore proper operation Add the coal in a couple of stages however it is...

Page 14: ...However when the stove is turned down and not much heat is needed the thermostat controlling the draft closes The gases now have no oxygen to burn and there is very little air movement through the st...

Page 15: ...EXTREMELY HOT FIRE THE CHIMNEY CONNECTOR AND CHIMNEY SHOULD BE INSPECTED AT LEAST TWICE MONTHLY DURING THE HEATING SEASON TO DETERMINE IF A SOOT BUILD UP HAS OCCURRED IF SOOT HAS ACCUMULATED IT SHOUL...

Page 16: ...till you are ready to use the furnace again in the fall Have the chimney inspected and cleaned if necessary If the optional filter housing is not installed you will need to clean the blower wheel Alwa...

Page 17: ...all be the responsibility of the original purchaser and the said Hitzer Inc shall have the final determination and be the final determiner as to whether or not said component is defective Any labor co...

Page 18: ...order for the above stated limited warranty to be effective and binding upon Hitzer Inc this portion herein must be detached and sent by the original owner to Hitzer Inc to the above stated address wi...

Reviews: