Chapter 10 LCD display and operating for SJ300/L300P series
88
2
nd
stage adjustable
selection (2
nd
motor)
>A294 2ACCEL
CHANGE TM
TM(change with 2CH terminal) /
FREE(change with setting)
89
2
nd
acceleration
frequency
>A095 ACCEL
CHFr 0000.00Hz
0.00 - 400.00 Hz
90
2
nd
acceleration
frequency(2
nd
motor)
>A295 2ACCEL
CHFr 0000.00Hz
0.00 - 400.00 Hz
91
2
nd
deceleration
frequency
>A096 DECEL
CHFr 0000.00Hz
0.00 - 400.00 Hz
92
2
nd
deceleration
frequency(2
nd
motor)
>A296 2DECEL
CHFr 000.00Hz
0.00 - 400.00 Hz
93
Acceleration pattern
selection
>A097 ACCEL
LINE Linear
Linear(straight line) / S-curve / U-curve
/RV-curve(reverse U-curve)
94
Deceleration pattern
selection
>A098 DECEL
LINE Linear
Linear(straight line) / S-curve / U-curve
/RV-curve(reverse U-curve)
(NOTE 1) L300P series : NOR / ECO
(NOTE 2) SJ300 series only .
(5/15)
No.
Function mode
Display
Data range
95 OI
start
>A101 INPUT-OI
EXS 0000.00Hz
0.00 – 400.00 Hz
96 OI
end
>A102 INPUT-OI
EXE 0000.00Hz
0.00 – 400.00 Hz
97 OI
start
rate
>A103 INPUT-OI
EX%S 20%
0 – 100
%
98 OI
end
rate
>A104 INPUT-OI
EX%E 100%
0 – 100
%
99 OI
start
selection
>A105 INPUT-OI
LEVEL 0Hz
OI-EXS(external start frequency) / 0Hz
100 O2
start
>A111 INPUT-O2
EXS +0000.00Hz
-400.00 – 400.00 Hz
101 O2
end
>A112 INPUT-O2
EXE +0000.00Hz
-400.00 – 400.00 Hz
102 O2 start rate
>A113 INPUT-O2
EX%S -100%
-100 – 100
%
103 O2 end rate
>A114 INPUT-O2
EX%E +100%
-100 – 100
%
104
Acceleration curve
constant
>A131 ACCEL
GAIN 02
01(small swelling)-10(large swelling)
105
Deceleration curve
constant
>A132 DECEL
GAIN 02
01(small swelling)-10(large swelling)
106 Retry
selection
>b001 IPS
POWER ALM
ALM(trip) / ZST(Ohz start) / RST(start after
equaling frequency) / FST(trip after equaling
frequency and deceleration stop)
107
Allowable
under-voltage
power failure time
>b002 IPS
TIME 1.0s
0.3 – 1.0 s
108 Retry wait time
>b003 IPS
WAIT 001.0s
0.3 – 100.0 s
109
Instantaneous
power
failure/under-voltag
e
trip during stop
>b004 IPS
TRIP OFF
OFF(invalid) / ON(valid) / DOFF(invalid during
stop and deceleration by stop command)