Operation of Trip mode
1. Pressing the [
] or [
] key to select trip mode at
navigation layer.
2. Pressing the [SET] key entries
into the below layer.This
mode will display the past trip information (6 times) and
warning
information (1 time). Each trip information includes
two pages.
(NOTE1) When trip happens, ALARM LED will be illuminated and the inverter can be reset via
pressing the [STOP/RESET] key.
(Parameter b087 decide the function of the [STOP/RESET] key)
(NOTE2) Because of different inverter states, trip time may be not saved and displayed.
(NOTE3) When trip happens, the backlight state becomes flicker whatever the state of
[Backlight Auto-off] is. (Refer to section 4.6)
SET
ESC
ERR1 P1 UnderVoltage
Output current 0.00A
TRIP M1-STOP ALL
10/07/18 11:52 Const.
Output FQ 6.00Hz
ERR1 P2 UnderVoltage
ON time 186hr
TRIP M1-STOP ALL
DC Voltage 172.3Vdc
RUN time 3hr
ERR6 P1 UnderVoltage
Output current 0.00A
TRIP M1-STOP ALL
10/07/18 10:20 Accel.
Output FQ 4.85Hz
ERR6 P2 UnderVoltage
ON time 186hr
TRIP M1-STOP ALL
DC Voltage 172.4Vdc
RUN time 3hr
WARNING M1-STOP ALL
Start FQ > Jog FQ
[b082] [A038]
E09.3
10/07/18 11:52 Const.
TRIP M1-STOP ALL
UnderVoltage
Err1 Page2
Err1 Page1
Err6 Page2
Err6 Page1
Err2
~
5
Page2
Err2
~
5
Page1
Chapter 4
Operation
(no data)
TRIP M1-STOP ALL
ERR1 P1
TRIP M1-STOP ALL
(no data)
ESC
SET
Display of no trip information