4
REMOTE CONTROLLER OPERATION
5.
REMOTE CONTROLLER OPERATION
5.1.
OPTIONAL LIQUID CRYSTAL REMOTE CONTROL PC-P1HE
Model: PC-P1HE
Order No.: 7E799954
Fan Speed Indicator
It Indicates the fan speed you have selected:
(High/Medium/Low)
Total Ventilatior Indicator
It indicates if Total ventilator has been selected.
A/C
only air conditioning
VENTI
only ventilation
A/C + VENTI when both have been selected
Operation Mode Indicator
Indicates the operation mode selected:
Fan, Cool, Heat, Dry, Auto (Cool/Heat)
Run Indicator (Red Lamp)
RUN/STOP Switch
MODE (Operation Mode Selection) Switch
FAN SPEED (Fan Speed Selection) Switch
Up & Down Panel Operation Switch
VENTI(Ventilator Operation) Switch
LOUVER (Swing Louver Operation) Switch
TIME (Time Setting) Switch
Increases and decreases the Set Time for timer
operation
¡
ON/OFF TIMER Switch
Used to activate or deactivate the timer operation
¢
CHECK Switch
£
RESET (Filter Reset Switch)
After cleaning the air filter, press the "RESET" button.
The filter indication
¦
will disappear and the next filter
cleaning time is reset. It also stops the run procedure.
¤
TEMP (Temperature Setting) Switch
¥
T.RUN (Test Run Indication)
Check (Check Indication)
These Tests appears when "TEST RUN" or "CHECK" is
being performed
¦
ABNML (Alarm) Indicator
"FILTER" Indicator
§
SET TEMP (Setting Temperature) Indicator
¨
ON/OFF Timer (Timer Operation Indicator)
Alarm Code Indicator
"NO FUNCTION" Indicator
©
CENTRAL (Central Control Indicator Operation)
Indicates that central station or CS-Net is being
performed
ª
Swing Louver Indicator
"DEFROST" Indicator
When opening the cover,
pull the cover toward the arrow direction
NOTE:
-
Do not use this system as constant temperature and
constant humidity control equipment.
-
In the case that the LOW fan speed is selected and
outdoor temperature is higher than 21°C, excessive load is
given to the compressor at heating operation.
Therefore, set the fan speed at HIGH or MEDIUM, since
safety devices may be activated.
-
When the system is started after a shutdown longer than
approximately 3 months, it is recommended that the
system be checked by your service contractor.
-
Turn OFF the main switch when the system is stopped for
a long period of time. If the main switch is not turned OFF,
electricity is consumed, because the oil heater is always
energized during compressor stopping.