8.3.2
Accessories factory-supplied with FSXNPE units
accessory
5HP
6HP
8HP
10HP
12HP
14HP
16HP
18HP
remarks
Accessory Pipe
ID22.2
→OD15.88
ID22.2
→OD19.05
ID22.2
→OD19.05
ID22.2
→OD19.05
ID22.2
→OD25.4
ID22.2
→OD28.58
OD15.88
→OD12.7
ID22.2
→OD28.58
-
ID22.2
→OD12.7
ID22.2
→OD15.88
ID22.2
→OD15.88
-
OD9.52
→OD12.7
-
ID22.2
→OD28.58
-
-
Cord Clamp
For Fixing Power
Source Wire
-
Rubber Bush
For Power Source Wire
Outlet (Bottom Base,
Piping Cover)
×2
×2
×2
×2
×2
×2
×2
×2
Ø70
For Transmission Wire
Outlet (Bottom Base,
Piping Cover)
×2
×2
×2
×2
×2
×2
×2
×2
Ø62
For Control Wire Outlet
(Bottom Base, Piping
Cover)
×2
×2
×2
×2
×2
×2
×2
×2
Ø38
Screw
×3
×3
×3
×3
×3
×3
×3
×3
for Fixing
Cord Clamp
and Spare
Combination Unit
Model Label
For Indication of
Combination Unit Model
Attach to
Outdoor Unit
A (Main Unit)
Protection plastic film
?
n o t e
Please contact your HITACHI distributor if any of the accessories has not been supplied with the unit.
8.3.3
Precautions for the installation of the outdoor unit
Order of installation of the units
When the installation and piping work for the multiple outdoor
units are performed, it is required that the arrangement for
outdoor units and piping length be determined. Perform securely
the installation work according to the following restrictions. If
the arrangement for outdoor units is incorrect, it may cause
flowback of the refrigerant and result in failure of outdoor unit.
Restrictions for 2 and 3 Units Combination
1
For 2 and 3 outdoor units combination, align the outdoor
units from largest capacity to smallest as A > B > C
and outdoor unit “A” should be connected to the piping
connection kit 1.
2
The piping length between the piping connection kit 1 and
the outdoor unit should be La < Lb < Lc < 10m.
3
For maintenance, attach “Main unit label” to the service
cover (back side surface) of the outdoor unit “A”.
C
C
B
B
A
A
L
a
L
a
L
b
L
b
L
c
L
c
>
>
<
<
Piping outlet
direction
Piping outlet
direction
Indoor
unit side
Piping
connection kit 1
Piping
connection kit 2
Piping con-
nection kit 2
(*)
(*)
(*)
(*)
(*): Keep the straight-line distance of 500 mm or more for piping after the piping connection kit.
Outdoor
unit
A
Outdoor
unit
B
Outdoor
unit
C
Outdoor
unit
C
Outdoor
unit
B
Outdoor
unit
A
Indoor
unit side
Piping
connection kit 1
PIPING WORK AND REFRIGERANT CHARGE
PMML0479 rev.4 - 11/2018
18
Summary of Contents for RAS-10FSXNPE
Page 2: ......
Page 14: ... i RAS 8 12 FSXNSE 1725 959 784 B A ...
Page 15: ... RAS 14FSXNSE 1725 1219 784 B A ...
Page 16: ... RAS 16 18 FSXNSE 1725 1219 784 B A ...
Page 17: ... RAS 20 24 FSXNSE 1725 1609 784 B A ...
Page 18: ... RAS 5 6 FSXNPE 1725 959 784 A B ...
Page 19: ... RAS 8 14 FSXNPE 1725 1219 784 A B ...
Page 20: ... RAS 16 18 FSXNPE 1725 1609 784 A B ...
Page 119: ......
Page 169: ......