– 60 –
Table 1 Fan speed by mode
Label name
FWSS
FWSOY
FWS
FWKAF
FWL
Hi
Set fan speed "Hi"
FWAH
Ultra Hi
FWAHH
Ultra Hi
FWH
Hi
Set fan speed "AUTO"
FWHH
FCSOY
FCS
FCL
FCAH
FCH
FCHH
FDSOY
FDS1
FDS2
Table 2 Room temperature shift value
Shift value
Fan speed "AUTO, Hi, Med"
SHIFTW
Fan speed "Lo, Silent, Sleep"
SFTSZW
SHIFTC
Dehumidifying operation
SHIFTD
Operation mode
Mode data file
LABEL NAME
REQUIRED VALUE OF UNIT SIDE
Fan speed mode
Operation
mode
Heating operation
Cooling operation
Cooling
operation
Dehumidifying
operation
Lo 1
Lo 2
Ultra Lo
Silent, Sleep
Lo
Heating
operation
Overload
Med
Hi
Ultra Hi
Hi
Set fan speed "AUTO"
Med
Set fan speed "Hi"
Silent, Sleep
Silent, Sleep
Lo
RAF-25FX8
RAF-35FX8
WMAX
4500
min
-1
5000
min
-1
WMAX2
4500
min
-1
5000
min
-1
WSTD
4000
min
-1
4550
min
-1
WJKMAX
3400
min
-1
3400
min
-1
WBEMAX
3200
min
-1
3200
min
-1
WSZMAX
3200
min
-1
3200
min
-1
CMAX
3600
min
-1
3800
min
-1
CSTD
2800
min
-1
3400
min
-1
CJKMAX
2200
min
-1
2200
min
-1
CBEMAX
1700
min
-1
1700
min
-1
CSZMAX
1700
min
-1
1700
min
-1
SDMAX
1300
min
-1
1300
min
-1
SDRPM
1100
min
-1
1100
min
-1
WMINHI
3200
min
-1
3200
min
-1
WMIN
3000
min
-1
3000
min
-1
CMINHI
1100
min
-1
1100
min
-1
CMIN
1100
min
-1
1100
min
-1
DMIN
1100
min
-1
1100
min
-1
STAROTP
5
℃
5
℃
STARCPL
2000
min
-1
2000
min
-1
STARCPH
3000
min
-1
3000
min
-1
STARCP2
0
min
-1
0
min
-1
STARCP3
1000
min
-1
1000
min
-1
STARTMW
60
sec.
60
sec.
STARTMC
60
sec.
60
sec.
STARTMD
60
sec.
60
sec.
STARTM2
0
sec.
0
sec.
STARTM3
120
sec.
120
sec.
PKOU
500
min
-1
500
min
-1
FZZY̲GN
1
1
FZZYTM
3
min.
3
min.
SHIFTW
0.00
℃
0.00
℃
SFTSZW
0.00
℃
0.00
℃
SFTOYW
0.00
℃
0.00
℃
SHIFTC
-0.66
℃
-0.66
℃
SHIFTD
-0.66
℃
-0.66
℃
CMNLMT
1100
min
-1
1100
min
-1
TEION
1.00
℃
1.00
℃
TEIOF
9.00
℃
9.00
℃
DFTIM̲COL
40
min.
40
min.
DFTIM̲FST
47
min.
47
min.
DFTIM̲OTP0
43
min.
43
min.
DFTIM̲OTP5
40
min.
40
min.
DFTIM̲OTP10
50
min.
50
min.
TDF411
30
sec.
30
sec.
TDF412
0
sec.
0
sec.
TDF413
0
sec.
0
sec.
DFRPM3
1300
min
-1
1300
min
-1
STARCPDL
1800
min
-1
1800
min
-1
STARCPDH
2000
min
-1
2000
min
-1
STARCPD2
1200
min
-1
1200
min
-1
STARTDF1
60
sec.
60
sec.
STARTDF2
70
sec.
70
sec.
DFMXTM
20
min.
20
min.
DFMAX
4300
min
-1
4550
min
-1
TDF431
70
sec.
70
sec.
TDF431̲CHG
30
sec.
30
sec.
DEFCOL
5
min.
5
min.
CLNTMW
8
min.
8
min.
CLNTMS
22
min.
22
min.
CLNCPW
2200
min
-1
2200
min
-1
CLNEVP
40.00
℃
40.00
℃
FWSS
350
min
-1
350
min
-1
FWSOY
550
min
-1
550
min
-1
FWS
650
min
-1
650
min
-1
FWKAF
750
min
-1
750
min
-1
FWL
780
min
-1
780
min
-1
FWAH
820
min
-1
920
min
-1
FWH
850
min
-1
950
min
-1
FWAHH
900
min
-1
950
min
-1
FWHH
900
min
-1
950
min
-1
FCSOY
500
min
-1
500
min
-1
FCS
650
min
-1
650
min
-1
FCL
780
min
-1
780
min
-1
FCAH
950
min
-1
950
min
-1
FCH
950
min
-1
980
min
-1
FCHH
980
min
-1
1050
min
-1
FDSOY
500
min
-1
500
min
-1
FDS1
650
min
-1
650
min
-1
FDS2
650
min
-1
650
min
-1
LABEL NAME
REQUIRED VALUE OF UNIT SIDE
RAF-25FX8
RAF-35FX8
Summary of Contents for RAC-25FX8
Page 44: ... 49 MODEL RAC 25FX8 RAC 35FX8 SELF CHECK SELF MODE FORCECOOLING RED RED RED ...
Page 48: ...BASIC MODE MODEL RAF 25FX8 RAF 35FX8 57 button 63 67 67 71 75 67 ...
Page 148: ... 166 SELF DIAGNOSIS LIGHTING MODE MODEL RAC 25FX8 RAC 35FX8 ...
Page 191: ...TC NO 0780EF RAF 25FX8 RAC 25FX8 RAF 35FX8 RAC 35FX8 Printed in Japan HRT ...