Revision A June 27, 2011
42 / 49
3) Resolution setting (DETAIL)
a) The cursor [
>
] is matched to
DETAIL
by the UP or DOWN command.
b) When the UP&DOWN command is transmitted, RESOLUTION MENU is displayed.
c) Use the Up or Down command to move the cursor [
>
] to
RESOLUTION
.
Under such a condition,
the resolution setting cuts when the SET command is transmitted and it changes.
Set command:
NORMAL
→
HIGH
NORMAL:
Standard resolution setting
HIGH:
Resolution is set higher than standard. (Factory setting)
4) Black level setting (PEDESTAL)
a) It is set to the best black level when shipping it and a right numerical value blinks to change
when the cursor [
>
] is moved to
PEDESTAL
by the UP or DOWN command and the SET
command is transmitted. The black level changes if the UP or DOWN command is transmitted in
the state.
Adjustment value range:
-128
~
000
~
+127
b) It returns to initialization (
000
) when the UP&DOWN command is transmitted. Blinking stops if
the SET command is transmitted with the numerical value has blinked and a set value is fixed.
5) Gamma correction setting (GAMMA)
Use the Up or Down command to move the cursor [
>
] to
GAMMA
.
Under such a condition, the
gamma setting cuts when the SET command is transmitted and it changes.
Set command:
ON
→
HIGH
→
OFF
ON:
Gamma ON
HIGH:
Gamma ON (High)
OFF:
Gamma OFF
6) Picture polarity setting (POLARITY)
When shipping it, it sets it to positive polarity (
POSITIVE
).
POSITIVE/NEGATIVE
of the image
polarity changes if the cursor is matched to
POLALITY
and a SET command is transmitted.
It is possible to see as a normal image by changing the setting to
NEGATIVE
(reverse) when
taking picture of the subject of the negative polarity such as the negative films.
◆ DETAIL MENU ◆
>
R E S O L U T I O N :N O R M A L
RET
END
……Resolution mode
……Return to Sub menu
……End(Menu display off
)
DETAIL menu
Summary of Contents for KP-D5010-S1