6 - 21
6-4 Adjustment Procedure
Start the adjustment program referring to “6-2-6 Starting and Terminating Adjustment Program”.
For the subsequent operation, operate the PC mouse while watching the PC monitor screen.
Information:
1) Display ×××× on subsequent PC screen shows the model name.
2) The numbers on PC screens show the operational procedure.
6-4-1 Data Initialize
Note:
Perform “Data Initialize” only after replacing the MAN circuit board. Executing “Data Initialize” will
initialize all adjustment data in EEPROM. After “Data Initialize”, be sure to perform all adjustment
items.
Procedure:
1) Check DATA INITIALIZE on the ADJUST MENU
screen.
2) Click the EXECUTE button on ADJUST MENU screen,
and then proceed with START TO SEND DATA? dialog.
3) Click the OK button in START TO SEND DATA? dialog:
After several seconds, “Data Initialize” will finish and
the ADJUST MENU screen will be restored. After that,
be sure to perform all adjustment items.
MANUAL ADJUSTMENT PROGRAM for SERVICE STATION
MODEL NAME:
××××
DATA INITIALIZE
EXECUTE
RETURN
PLEASE SELECT ADJUST
ADJUST MENU
SAMPLING PULSE
AUTO IRIS CONTROL
MATRIX
CHROMA GAIN
AUTO FUCUS
STABILIZER
SPOT NOISE
LCD
EVF
VIDEO LEVEL
BURST LEVEL
2
1
DATA INITIALIZE
START TO SEND DATA?
OK
CANCEL
3
ADJUST MENU screen
START TO SEND DATA? dialog
Adjustment > Adjustment Procedure