6
7
CP-X807(EDX50WL)
Command Format
[TCP #23]
1. Protocol
Consist of header (7 bytes) + command data (6 bytes)
2. Header
BE + EF + 03 + 06 + 00 + C CRC_high
CRC_low: Lower byte of CRC flag for command data
CRC_high: Upper byte of CRC flag for command data
3. Command data
Command data chart
byte_0
byte_1
byte_2
byte_3
byte_4
byte_5
Action
Type
Setting code
low
high
low
high
low
high
Action (byte_0 - 1)
Action
Classification
Content
1
Set
Change setting to desired value.
2
Get
Read projector internal setup value.
4
Increment
Increment setup value by 1.
5
Decrement
Decrement setup value by 1.
6
Execute
Run a command.
Requesting projector status (Get command)
(1) Send the following request code from the PC to the projector.
Command data (‘02H’ + ‘00H’ + type (2 bytes) + ‘00H’ + ‘00H’)
(2) The projector returns the response code
‘1DH’ + data (2 bytes)
to the PC.
Changing the projector settings (Set command)
(1) Send the following setting code from the PC to the projector.
Command data (‘01H’ + ‘00H’ + type (2 bytes) + setting code (2 bytes))
(2) The projector changes the setting based on the above setting code.
(3) The projector returns the response code
‘06H’
to the PC.
Using the projector default settings (Reset Command)
(1) The PC sends the following default setting code to the projector.
Command data (‘06H’ + ‘00H’ + type (2 bytes) + ‘00H’ + ‘00H’)
(2) The projector changes the specified setting to the default value.
(3) The projector returns the response code
‘06H’
to the PC.
Increasing the projector setting value (Increment command)
(1) The PC sends the following increment code to the projector.
Command data (‘04H’ + ‘00H’ + type (2 bytes) + ‘00H’ + ‘00H’)
(2) The projector increases the setting value on the above setting code.
(3) The projector returns the response code
‘06H’
to the PC.
Summary of Contents for CP-X807W
Page 23: ...23 CP X807 EDX50WL Fig 3 Wireless Network Unit Configuration Fig 4 Execute ipconfig ...
Page 87: ...SM0598 POWER UNIT BALLAST SHEET 1 DAUGHTER BOARD 1 POWER BOARD SUB 1 CP X807 EDX50WL 87 ...
Page 88: ...SM0598 POWER UNIT BALLAST SHEET 2 DAUGHTER BOARD 1 POWER BOARD SUB 1 CP X807 EDX50WL 88 ...
Page 89: ...SM0598 POWER UNIT BALLAST SHEET 3 TRIGGER TRANSFORMER CP X807 EDX50WL 89 ...
Page 90: ...SM0598 POWER UNIT CIRCUIT SHEET 1 CP X807 EDX50WL 90 ...
Page 91: ...SM0598 POWER UNIT CIRCUIT SHEET 2 CP X807 EDX50WL 91 ...