8
2
CP-X807(EDX50WL)
Names
Operation Type
Header
Command Data
CRC
Action
Type
Setting Code
MAGNIFY
Get
BE EF
03
06 00
7C D2
02 00
07 30
00 00
Increment
BE EF
03
06 00
1A D2
04 00
07 30
00 00
Decrement
BE EF
03
06 00
CB D3
05 00
07 30
00 00
FREEZE
Set
NORMAL
BE EF
03
06 00
83 D2
01 00
02 30
00 00
FREEZE
BE EF
03
06 00
13 D3
01 00
02 30
01 00
Get
BE EF
03
06 00
B0 D2
02 00
02 30
00 00
e-SHOT
Set
OFF
BE EF
03
06 00
3A C3
01 00
00 35
00 00
IMAGE 1
BE EF
03
06 00
AA C2
01 00
00 35
01 00
IMAGE 2
BE EF
03
06 00
5A C2
01 00
00 35
02 00
IMAGE 3
BE EF
03
06 00
CA C3
01 00
00 35
03 00
IMAGE 4
BE EF
03
06 00
FA C1
01 00
00 35
04 00
Get
BE EF
03
06 00
09 C3
02 00
00 35
00 00
e-SHOT IMAGE1
Delete
Execute
BE EF
03
06 00
71 C3
06 00
01 35
00 00
e-SHOT IMAGE2
Delete
Execute
BE EF
03
06 00
35 C3
06 00
02 35
00 00
e-SHOT IMAGE3
Delete
Execute
BE EF
03
06 00
C9 C2
06 00
03 35
00 00
e-SHOT IMAGE4
Delete
Execute
BE EF
03
06 00
BD C3
06 00
04 35
00 00
Summary of Contents for CP-X807W
Page 23: ...23 CP X807 EDX50WL Fig 3 Wireless Network Unit Configuration Fig 4 Execute ipconfig ...
Page 87: ...SM0598 POWER UNIT BALLAST SHEET 1 DAUGHTER BOARD 1 POWER BOARD SUB 1 CP X807 EDX50WL 87 ...
Page 88: ...SM0598 POWER UNIT BALLAST SHEET 2 DAUGHTER BOARD 1 POWER BOARD SUB 1 CP X807 EDX50WL 88 ...
Page 89: ...SM0598 POWER UNIT BALLAST SHEET 3 TRIGGER TRANSFORMER CP X807 EDX50WL 89 ...
Page 90: ...SM0598 POWER UNIT CIRCUIT SHEET 1 CP X807 EDX50WL 90 ...
Page 91: ...SM0598 POWER UNIT CIRCUIT SHEET 2 CP X807 EDX50WL 91 ...