CP-X807(EDX50WL)
6-13 HIDDEN SERVICE MENU
By the control panel
By the remote control transmitter
1. Display the Advanced menu by the
“MENU” button.(If EASY MENU
appears, choose “Go to Advanced
menu” to display ADVANCED
MENU.)
2. Select the “OPTION” on the menu.
3. Continue press the button [ ] fi rst,
then press the button [ ] together
with “INPUT”, and hold for 3 seconds.
1. Display the menu by the “MENU”
button. (If EASY MENU appears,
choose “Go to Advanced menu” to
display ADVANCED MENU.)
2. Select the “OPTION” on the menu.
3. Press the “MAGNIFY OFF” button.
Next hold the “MAGNIFY OFF”
button for 3 seconds.
To display the OSD for “HIDDEN SERVICE MENU” set up.
HIDDEN SERVICE
AIR-SENSOR EXECUTE
LAMP ALARM
NONE
STARTUP TYPE
1
BNC TERMINATION
TTL
SYNC SLICE LEVEL-1 4
SYNC SLICE LEVEL-2 4
PJLink
TURN OFF
PANEL TIME
1234h
NETWORK RESET
SOFT RESET
6-14 RUN TIME window
AIR - SENSOR
Execute this item to adjust the air sensor.
LAMP ALARM
Select the lamp alarm level. 3 Level
ļ
1 Level
ļ
None
“3 Level” shows three kinds of lamp-messages according to the LAMP TIME count.
“1 Level” shows one kind of lamp-message according to the LAMP TIME count.
“None” shows no lamp-messages. It is the factory default setting.
STARTUP TYPE
Select the startup screen type. 1 : shows Hitachi Logo
2 : No Hitachi Logo
BNC TERMINATION
Select the RGB2 (BNC) Terminator. 75 ohm
ļ
TTL
SYNC SLICE LEVEL-1
Set the Sync separation slice level of the RGB1. (1~7)
SYNC SLICE LEVEL-2
Set the Sync separation slice level of the RGB2 (BNC). (1~7)
PJLink
Select the PJLink. Turn off
ļ
Turn on
PANEL TIME
Use time of LCD panel. Reset the PANEL TIME whenever you changed the LCD/LENS prism assembly.
NETWORK RESET
If this is executed, all of the network setting are initialized.
SOFT RESET
If this is executed, all of the user data is initialized.Never use it when not required.
Set operating time display method (accumulated lamp time display method)
1. Select
“ OPTION” from the Advanced menu, then place the cursor on the “LAMP TIME”.
2. Press the [ ], [ENTER] or [RESET] button.
3. Press the [Reset] button once, then press [KEYSTONE] button of the remote control for 3 seconds or more to display
the screen shown below. (The menu will close after 10 seconds if there are no further operations.)
4. Use
[
] or [
] to select the usage status number. (The usage status is as shown below.)
Usage status number
0 ..... Total usage status
1 ..... Current usage status
2 ..... Usage status before first reset
3 ..... Usage status before second reset
||
9 ..... Usage status before eighth reset
RUN TIME
LAMP
Lamp time
1234 h
h
h
h
NORMAL
Lamp time(Normal)
1000
WHISPER
Lamp time(Whisper)
234
AC
2000
AC energizing time
On
Number of times on
1
Off
Number of times off
No.0
Usage status number(See below)
0
Summary of Contents for CP-X807W
Page 23: ...23 CP X807 EDX50WL Fig 3 Wireless Network Unit Configuration Fig 4 Execute ipconfig ...
Page 87: ...SM0598 POWER UNIT BALLAST SHEET 1 DAUGHTER BOARD 1 POWER BOARD SUB 1 CP X807 EDX50WL 87 ...
Page 88: ...SM0598 POWER UNIT BALLAST SHEET 2 DAUGHTER BOARD 1 POWER BOARD SUB 1 CP X807 EDX50WL 88 ...
Page 89: ...SM0598 POWER UNIT BALLAST SHEET 3 TRIGGER TRANSFORMER CP X807 EDX50WL 89 ...
Page 90: ...SM0598 POWER UNIT CIRCUIT SHEET 1 CP X807 EDX50WL 90 ...
Page 91: ...SM0598 POWER UNIT CIRCUIT SHEET 2 CP X807 EDX50WL 91 ...