MegaRAID
WebBIOS
2-51
Hitachi Compute Rack 210H/220H BIOS Guide
6.
Wait until the processing is completed to 100%.
A guideline of initialization time is shown in the following table.
Table 2-18:
Guideline of initialization
Single drive capacity
Initialization time
146 GB (SAS / 2.5 inch type HDD)
Approximately 16 minutes
300 GB (SAS / 2.5 inch type HDD)
Approximately 40 minutes
450 GB (SAS / 2.5 inch type HDD)
Approximately 60 minutes
600 GB (SAS / 2.5 inch type HDD)
Approximately 80 minutes
900 GB (SAS / 2.5 inch type HDD)
Approximately 120 minutes
1.2 TB (SATA2 / 2.5 inch type HDD)
Approximately 160 minutes
500 GB (SATA2 / 2.5 inch type HDD)
Approximately 670 minutes
1 TB (SATA2 / 2.5 inch type HDD)
Approximately 1340 minutes
100 GB (SATA2 / 2.5 inch type SSD)
Approximately 10 minutes
200 GB (SATA2 / 2.5 inch type SSD)
Approximately 20 minutes
The initialization time varies depending on the physical drive
capacity regardless of the RAID level or virtual drive capacity.
7.
When initialization is completed to 100%, click
Home
to return to the main
menu.