2-14
MegaRAID
WebBIOS
Hitachi Compute Rack 210H/220H BIOS Guide
Controller properties submenu 1
Click
Next
in the
Controller Information menu 2
window. The following
window is displayed.
The following table shows description of menu items in the window.
Table 2-7: Controller properties submenu 1 items
Menu items
Description
Setting/display value
Battery Backup
1
Status of cache backup module
installation
None / Present
Set Factory Defaults
2
Returning all the settings to their
defaults values
Unchangable
Cluster Mode
3
Setting the cluster mode
[Disabled]
Rebuild Rate
4
Priority of rebuilding
0 to 100 / [30]
BGI Rate
4
Priority of background initializing
0 to 100 / [30]
CC Rate
3
Priority of consistency check
0 to 100 / [30]
Reconstruction Rate
4
Priority of capacity expansion
0 to 100 / [30]
NCQ
3
Enabling or disabling the NCQ
command
[Enabled] / Disabled
Coercion Mode
5
Setting the capacity control for
the physical disk used for disk
array building
[None (using the entire capacity)] /
128MB-way (using a capacity as a
multiple of 128MB) / 1GB-way (using
a capacity as a multiple of 1GB)
S.M.A.R.T Polling
4
Setting the interval of S.M.A.R.T.
reporting
0 to 65535 / 300 / [600]
Alarm Control
Sounding the buzzer on the
controller in the event of failure at
a connected device
[Disabled] / Enabled / Silence