Rack Mount: RMK12, RMK17
Quick Start
Using the RMK12 Adder rack mount
(see over for RMK17)
1 Install the empty rack mount into your 19” rack frame and fully secure it.
2 Place a compatible module into each side of the rack mount so that their rear
panels butt up against the small pegs located on each of the side walls.
3 Locate the supplied thumbscrew and spacer.
4 Insert the thumbscrew through the spacer; then insert into the
small hole at the end of the center divider
(A)
.
5 Gently tighten the thumbscrew so that the
spacer engages with the inner edges of the two
modules and holds them in place
(B)
.
6 Place the power adapters in the rear section
of the rack mount and connect them to their
respective modules.
7 Make all other necessary connections to the modules.
(A)
(B)
Using a blanking plate when a single module is
installed
In order to maintain suitable cooling airflow, if a single module is installed within the
rack mount, you are recommended to install an optional blanking plate: RMK12-BP
Note: The outer edge of the blanking plate needs to overlap the ears of the rack
mount itself, so you need to either install the blanking plate before the tray is installed
or briefly remove the mounting bolts on the blanked side (while supporting the
weight of the tray) to allow the blanking plate to be put in place.
RMK12-BP
blanking plate