Server blade
Firmware
BMC, EFI
Management module
CB 520H B4
10-00 or later
A0285 or later
CB 520X B1
06-04 or later
A0235 or later
CB 520X B2
09-06 or later
A0250 or later
CB 520X B3
11-00 or later
A0315 or later
Confirming firmware version of the management module
1
.
Confirm firmware version on Management Module. See "
" section.
2
.
For CB 540A B1, if firmware version is earlier than ver. A0145, you need
to update the version to A0145 or later.
For CB 520H B2, if firmware version is earlier than ver. A0205, you need
to update the version to A0205 or later.
For CB 520H B3 or CB 520X B1, if firmware version is earlier than ver.
A0235, you need to update the version to A0235 or later.
For CB 520H B4, if firmware version is earlier than ver. A0285, you need
to update the version to A0285 or later.
For CB 520X B2, if firmware version is earlier than ver. A0250, you need
to update the version to A0250 or later.
For CB 520X B3, if firmware version is earlier than ver. A0315, you need
to update the version to A0315 or later.
Confirming BMC/EFI firmware version of the server blade
1
.
Confirm firmware version on server blade. See "
" section.
2
.
For CB 540A B1, if firmware version is earlier than ver. 03-14, you need
to update the version to 03-14 or later.
For CB 520H B2, if firmware version is earlier than ver. 04-30, you need
to update the version to 04-30 or later.
See "
Updating BMC/EFI firmware on server blade on page 9-2
" section.
How to disable LOM and mount mezzanine cards.
Updating FRU.
1
.
[For CB 520H B1/B2/B3/B4, CB 540A B1, and Non-SMP CB 520X
B1/B2/B3]
Select Resources tab and select Modules > Server Blades > a target
blade that should update the FRU information.
[For SMP CB 520X B1/B2/B3]
Change LOM configuration
10-5
Hitachi Compute Blade 500 Series System Service Manual
Summary of Contents for CB 520A A1
Page 26: ...xxvi Preface Hitachi Compute Blade 500 Series System Service Manual ...
Page 152: ...4 64 Common process for replacement Hitachi Compute Blade 500 Series System Service Manual ...
Page 294: ...6 12 Identifying RAID rebuild status Hitachi Compute Blade 500 Series System Service Manual ...
Page 432: ...9 16 Updating firmware Hitachi Compute Blade 500 Series System Service Manual ...
Page 439: ...Change LOM configuration 10 7 Hitachi Compute Blade 500 Series System Service Manual ...
Page 442: ...10 10 Change LOM configuration Hitachi Compute Blade 500 Series System Service Manual ...
Page 450: ...10 18 Change LOM configuration Hitachi Compute Blade 500 Series System Service Manual ...
Page 464: ...11 14 Troubleshooting Hitachi Compute Blade 500 Series System Service Manual ...
Page 465: ...Hitachi Compute Blade 500 Series System Service Manual ...