Figure 4-53 Power off procedure of failed management module
(B) Press and hold the Power switch for four seconds or more
This procedure forces the management module to power off.
1
.
Ensure that Power LED lights in green.
2
.
Press and hold the Shutdown switch until Power LED turns to light in
amber.
3
.
Release the Shutdown switch.
Figure 4-54 Power LED and Shutdown switch
Power off the switch module
Use the following procedure to power down the switch module.
(A) Use a Web console
This procedure initiates a remote power off for the failed switch module.
1
.
Ensure that Power LED lights on green.
2
.
Logon to the Web console and select Resource.
3
.
Select Modules > All Modules > Switch modules > the failed
module.
4
.
Select Condition tab.
5
.
Click Power OFF.
6
.
Ensure that the shutdown was completed and Power LED lights in amber.
4-62
Common process for replacement
Hitachi Compute Blade 500 Series System Service Manual
Summary of Contents for CB 520A A1
Page 26: ...xxvi Preface Hitachi Compute Blade 500 Series System Service Manual ...
Page 152: ...4 64 Common process for replacement Hitachi Compute Blade 500 Series System Service Manual ...
Page 294: ...6 12 Identifying RAID rebuild status Hitachi Compute Blade 500 Series System Service Manual ...
Page 432: ...9 16 Updating firmware Hitachi Compute Blade 500 Series System Service Manual ...
Page 439: ...Change LOM configuration 10 7 Hitachi Compute Blade 500 Series System Service Manual ...
Page 442: ...10 10 Change LOM configuration Hitachi Compute Blade 500 Series System Service Manual ...
Page 450: ...10 18 Change LOM configuration Hitachi Compute Blade 500 Series System Service Manual ...
Page 464: ...11 14 Troubleshooting Hitachi Compute Blade 500 Series System Service Manual ...
Page 465: ...Hitachi Compute Blade 500 Series System Service Manual ...