26
.
Verify that the power LED lights in green after blinking, and that the
primary LED is off.
27
.
Set up TOD if you need.
See
Time of Day (TOD) clock setup procedure on page 4-44
section.
28
.
Verify that the replacement was successful through the MAR log.
See
Alert information identification procedure on page 4-5
section.
29
.
Turn off the maintenance mode from web console.
See
Maintenance mode on/off procedure on page 4-10
section.
Replacing a management module (non-redundant)
This procedure describes how to replace a management module under the
non-redundant configuration. Under this configuration, the single
management module is installed in chassis.
Removing a management module
1
.
Put on an anti-static wrist strap.
2
.
Web console login procedure on page 4-3
section.
3
.
Turn on LID LED for identifying the target module.
See
Identify LED (LID) on/off procedure on page 4-7
section.
4
.
Turn on the maintenance mode from web console.
See
Maintenance mode on/off procedure on page 4-10
section.
5
.
Identify F/W version and take notes of it.
See
F/W version identification procedure on page 4-22
section.
6
.
Back up the configuration data to the USB memory in the front panel or
any storage in the local PC. See
Backup/restore procedure on page 4-30
section.
7
.
Select Resources tab on the web console and select System > Network
> Internal LAN.
8
.
Confirm IP address and Subnet mask.
5-106
Replacing parts
Hitachi Compute Blade 500 Series System Service Manual
Summary of Contents for CB 520A A1
Page 26: ...xxvi Preface Hitachi Compute Blade 500 Series System Service Manual ...
Page 152: ...4 64 Common process for replacement Hitachi Compute Blade 500 Series System Service Manual ...
Page 294: ...6 12 Identifying RAID rebuild status Hitachi Compute Blade 500 Series System Service Manual ...
Page 432: ...9 16 Updating firmware Hitachi Compute Blade 500 Series System Service Manual ...
Page 439: ...Change LOM configuration 10 7 Hitachi Compute Blade 500 Series System Service Manual ...
Page 442: ...10 10 Change LOM configuration Hitachi Compute Blade 500 Series System Service Manual ...
Page 450: ...10 18 Change LOM configuration Hitachi Compute Blade 500 Series System Service Manual ...
Page 464: ...11 14 Troubleshooting Hitachi Compute Blade 500 Series System Service Manual ...
Page 465: ...Hitachi Compute Blade 500 Series System Service Manual ...