--- 22 ---
1. Remove the two Tapping Screws (W/Flange) D4 x 25 (Black)
[133]
and the four Tapping Screws (W/Flange)
D4 x 20 (Black)
[140]
, then remove Switch Handle (A)
[134]
.
2. Remove the wire of the Laser Module
[11]
from the Switching Power Supply
[142]
. (Only the Model C 10FCH)
3. Remove the Brush Cap
[165]
and the Carbon Brush
[164]
.
4. Remove the four Machine Screws (W/Washers) M5 x 40 (Black)
[160]
. Then the Housing Ass'y
[161]
can be
removed from the Gear Case Ass'y
[130]
together with Switch Handle (B)
[148]
. The Lock Lever
[153]
and
the Armature Ass'y
[149]
can also be removed.
5. Cut the internal wires at the root of the Connector
[137]
to disconnect the Cord
[131]
and the Stator Ass'y
[158]
. Otherwise, the internal wires become short and they cannot be wired in reassembly work. (See "11-4.
Wiring Diagram" for details.)
6. Remove the Tapping Screw (W/Flange) D4 x 16
[135]
. Then remove the Cord Clip
[136]
, Cord
[131]
and Cord
Armor
[132]
.
7. Remove two Hex. Hd. Tapping Screws D5 x 50
[157]
to remove the Brush Terminal
[159]
from the Brush
Holder
[163]
. Gently tap the surface of the Housing Ass'y
[161]
where the Gear Case Ass'y
[130]
was
mounted with a plastic hammer to remove the Stator Ass'y
[158]
.